Within-day and between-day repeatability of measurements with an electronic nose in patients with COPD

Maria Bofan, Nadia Mores, Marco Baron, Malgorzata Dabrowska, Salvatore Valente, Maurizio Schmid, Markus Schmid, Andrea Trové, Silvia Conforto, Gina Zini Tanzi, Paola Cattani Franchi, Leonello Fuso, Antonella Mautone, Chiara Mondino, Gabriella Pagliari, Tommaso D'Alessio, Paolo Montuschi

Risultato della ricerca: Contributo in rivistaArticolo in rivista

60 Citazioni (Scopus)

Abstract

Electronic noses (e-noses), artificial sensor systems generally consisting of chemical sensor arrays for the detection of volatile compound profiles, have potential applications in respiratory medicine. We assessed within-day and between-day repeatability of an e-nose made from 32 sensors in patients with stable chronic obstructive pulmonary disease (COPD). We also compared between-day repeatability of an e-nose, fraction of exhaled nitric oxide (FENO) and pulmonary function testing. Within-day and between-day repeatability for the e-nose was assessed in two breath samples collected 30 min and seven days apart, respectively. Repeatability was expressed as an intraclass correlation coefficient (ICC). All sensors had ICC above 0.5, a value that is considered acceptable for repeatability. Regarding within-day repeatability, ICC ranged from 0.75 to 0.84 (mean = 0.80 ± 0.004). Sensors 6 and 19 were the most reproducible sensors (both, ICC = 0.84). Regarding between-day repeatability, ICC ranged from 0.57 to 0.76 (mean = 0.68 ± 0.01). Sensor 19 was the most reproducible sensor (ICC = 0.76). Within-day e-nose repeatability was greater than between-day repeatability (P < 0.0001). Between-day repeatability of FENO (ICC = 0.91) and spirometry (ICC range = 0.94-0.98) was greater than that of e-nose (mean ICC = 0.68). In patients with stable COPD, the e-nose used in this study has acceptable within-day and between-day repeatability which varies between different sensors.
Lingua originaleEnglish
pagine (da-a)017103-017103
Numero di pagine1
RivistaJournal of Breath Research
Volume7
DOI
Stato di pubblicazionePubblicato - 2013

Keywords

  • Aged
  • Breath Tests
  • Exhalation
  • Female
  • Humans
  • Male
  • Nitric Oxide
  • Pulmonary Disease, Chronic Obstructive
  • Reproducibility of Results
  • Spirometry

Fingerprint

Entra nei temi di ricerca di 'Within-day and between-day repeatability of measurements with an electronic nose in patients with COPD'. Insieme formano una fingerprint unica.