TY - JOUR
T1 - Tunneling of Mesh during Ventral Rectopexy: Technical Aspects and Long-Term Functional Results
AU - Campennì, Paola
AU - Marra, Angelo Alessandro
AU - De Simone, Veronica
AU - Litta, Francesco
AU - Parello, Angelo
AU - Ratto, Carlo
PY - 2023
Y1 - 2023
N2 - Avoiding the extensive damage of pelvic structures during ventral rectopexy could minimize secondary disfunctions. The objective of our observational study is to assess the safety and functional efficacy of a modified ventral rectopexy. In the modified ventral rectopexy, a retroperitoneal tunnel was created along the right side of rectum, connecting two peritoneal mini-incisions at the Douglas pouch and sacral promontory. The proximal edge of a polypropylene mesh, sutured over the ventral rectum, was pulled up through the retroperitoneal tunnel and fixed to the sacral promontory. In all patients, radiopaque clips were placed on the mesh, making it radiographically “visible”. Before surgery and at follow up visits, Altomare, Longo, CCSS, PAC-SYM, and CCFI scores were collected. From March 2010 to September 2021, 117 patients underwent VR. Modified ventral rectopexy was performed in 65 patients, while the standard ventral rectopexy was performed in 52 patients. The open approach was used in 97 cases (55 and 42 patients in modified and standard VR, respectively), while MI surgery was used in 20 cases (10 and 10 patients in modified and standard VR, respectively). A slightly shorter operative time and hospital stay were observed following modified ventral rectopexy (though this was not statistically significant). Similar overall complication rates were registered in the modified vs. standard ventral rectopexies (4.6% vs. 5.8%, p = 0.779). At follow-up, the Longo score (14.0 ± 8.6 vs. 11.0 ± 8.2, p = 0.042) and “delta” values of Altomare (9.2 ± 6.1 vs. 5.9 ± 6.3, p = 0.008) and CCSS (8.4 ± 6.3 vs. 6.1 ± 6.1, p = 0.037) scores were significantly improved in the modified ventral rectopexy group. A similar occurrence of symptoms recurrence was diagnosed in the two groups. Radiopaque clips helped to accurately diagnose mesh detachment/dislocation. The proposed modified VR seems to be feasible and safe. Marking the mesh intraoperatively seems useful.
AB - Avoiding the extensive damage of pelvic structures during ventral rectopexy could minimize secondary disfunctions. The objective of our observational study is to assess the safety and functional efficacy of a modified ventral rectopexy. In the modified ventral rectopexy, a retroperitoneal tunnel was created along the right side of rectum, connecting two peritoneal mini-incisions at the Douglas pouch and sacral promontory. The proximal edge of a polypropylene mesh, sutured over the ventral rectum, was pulled up through the retroperitoneal tunnel and fixed to the sacral promontory. In all patients, radiopaque clips were placed on the mesh, making it radiographically “visible”. Before surgery and at follow up visits, Altomare, Longo, CCSS, PAC-SYM, and CCFI scores were collected. From March 2010 to September 2021, 117 patients underwent VR. Modified ventral rectopexy was performed in 65 patients, while the standard ventral rectopexy was performed in 52 patients. The open approach was used in 97 cases (55 and 42 patients in modified and standard VR, respectively), while MI surgery was used in 20 cases (10 and 10 patients in modified and standard VR, respectively). A slightly shorter operative time and hospital stay were observed following modified ventral rectopexy (though this was not statistically significant). Similar overall complication rates were registered in the modified vs. standard ventral rectopexies (4.6% vs. 5.8%, p = 0.779). At follow-up, the Longo score (14.0 ± 8.6 vs. 11.0 ± 8.2, p = 0.042) and “delta” values of Altomare (9.2 ± 6.1 vs. 5.9 ± 6.3, p = 0.008) and CCSS (8.4 ± 6.3 vs. 6.1 ± 6.1, p = 0.037) scores were significantly improved in the modified ventral rectopexy group. A similar occurrence of symptoms recurrence was diagnosed in the two groups. Radiopaque clips helped to accurately diagnose mesh detachment/dislocation. The proposed modified VR seems to be feasible and safe. Marking the mesh intraoperatively seems useful.
KW - fecal incontinence
KW - obstructed defecation syndrome
KW - ventral rectopexy
KW - rectal prolapse
KW - pelvic disorders
KW - fecal incontinence
KW - obstructed defecation syndrome
KW - ventral rectopexy
KW - rectal prolapse
KW - pelvic disorders
UR - http://hdl.handle.net/10807/236054
U2 - 10.3390/jcm12010294
DO - 10.3390/jcm12010294
M3 - Article
SN - 2077-0383
VL - 12
SP - 294
EP - 294
JO - Journal of Clinical Medicine
JF - Journal of Clinical Medicine
ER -