Abstract
A 59-year-oldman underwent orthotopic liver transplantation; liver re-transplantation was needed 24 hours later owing to primary liver failure. A large incisional hernia was repaired 5 years later. Increases in his liver function tests were noted 6 years later and magnetic resonance cholangiography showed an anastomotic biliary stricture.
Magnetic compression anastomosis was proposed; the patient signed a specific informed consent for compassionate use.
| Lingua originale | Inglese |
|---|---|
| pagine (da-a) | N/A-N/A |
| Numero di pagine | 21 |
| Rivista | Endoscopy |
| Volume | 2021 |
| DOI | |
| Stato di pubblicazione | Pubblicato - 2021 |
Keywords
- Anastomotic stricture
- Liver transplantation
- Magnet