The European Registry for Patients with Mechanical Circulatory Support (EUROMACS): third Paediatric (Paedi-EUROMACS) report

Theo M.M.H. De By, Martin Schweiger, Hina Hussain, Antonio Amodeo, Thomas Martens, Ad J.J.C. Bogers, Kevin Damman, Can Gollmann-Tepeköylü, Michael Hulman, Attilio Iacovoni, Ulrike Krämer, Antonio Loforte, Carlo Pace Napoleone, Petr Němec, Ivan Netuka, Mustafa Özbaran, Luz Polo, Yuri Pya, Faiz Ramjankhan, Eugen SandicaJoanna Sliwka, Brigitte Stiller, Alexander Kadner, Alessio Franceschini, Timothy Thiruchelvam, Daniel Zimpfer, Bart Meyns, Felix Berger, Oliver Miera

Risultato della ricerca: Contributo in rivistaArticolo in rivista

Abstract

OBJECTIVES: A third paediatric report has been generated from the European Registry for Patients with Mechanical Circulatory Support (EUROMACS). The purpose of EUROMACS, which is operated by the European Association for Cardio-Thoracic Surgery, is to gather data related to durable mechanical circulatory support for scientific purposes and to publish reports with respect to the course of mechanical circulatory support therapy. Since the first report issued, efforts to increase compliance and participation have been extended. Additionally, the data provided the opportunity to analyse patients of younger age and lower weight. METHODS: Participating hospitals contributed pre-, peri- and long-term postoperative data on mechanical circulatory support implants to the registry. Data for all implants in paediatric patients (<19 years of age) performed from 1 January 2000 to 31 December 2020 were analysed. This report includes updates of patient characteristics, implant frequency, outcome (including mortality rates, transplants and recovery rates) as well as adverse events including neurological dysfunction, device malfunction, major infection and bleeding. RESULTS: Twenty-five hospitals contributed 537 registered implants in 480 patients. The most frequent aetiology of heart failure was any form of cardiomyopathy (59%), followed by congenital heart disease and myocarditis (15% and 14%, respectively). Competing outcomes analysis revealed that a total of 86% survived to transplant or recovery or are ongoing; at the 2-year follow-up examination, 21.9% died while on support. At 12 months, 45.1% received transplants, 7.5% were weaned from their device and 20.8% died. The 3-month adverse events rate was 1.59 per patient-year for device malfunction including pump exchange, 0.7 for major bleeding, 0.78 for major infection and 0.71 for neurological events. CONCLUSIONS: The overall survival rate was 79.2% at 12 months following ventricular assist device implant. The comparison of survival rates of the early and later eras shows no significant difference. A focus on specific subgroups showed that survival was less in patients of younger age (<1 year of age; P = 0.01) and lower weight (<20 kg; P = 0.015). Transplant rates at 6 months continue to be low (33.2%).
Lingua originaleEnglish
pagine (da-a)N/A-N/A
RivistaEuropean Journal of Cardio-thoracic Surgery
Volume62
DOI
Stato di pubblicazionePubblicato - 2022

Keywords

  • Congenital heart disease
  • End-stage heart failure
  • Mechanical circulatory support
  • Paediatric patients
  • Registry
  • Ventricular assist device

Fingerprint

Entra nei temi di ricerca di 'The European Registry for Patients with Mechanical Circulatory Support (EUROMACS): third Paediatric (Paedi-EUROMACS) report'. Insieme formano una fingerprint unica.

Cita questo