The Colon Endoscopic Bubble Scale (CEBuS): A two-phase evaluation study

Filipe Taveira, Cesare Hassan, Michal F. Kaminski, Thierry Ponchon, Robert Benamouzig, Marek Bugajski, Flore De Castelbajac, Paola Cesaro, Hasnae Chergui, Loredana Goran, Leonardo Minelli Grazioli, Martin Janičko, Wladyslaw Januszewicz, Laura Lamonaca, Jamila Lenz, Lucian Negreanu, Alessandro Repici, Cristiano Spada, Cristiano Spada, Marco SpadacciniMonica State, Jakub Szlak, Eduard Veseliny, Mário Dinis-Ribeiro, Miguel Areia

Risultato della ricerca: Contributo in rivistaArticolo in rivista

Abstract

Background To date, no scale has been validated to assess bubbles associated with bowel preparation. This study aimed to develop and assess the reliability of a novel scale - the Colon Endoscopic Bubble Scale (CEBuS). Methods This was a multicenter, prospective, observational study with two online evaluation phases of 45 randomly distributed still colonoscopy images (15 per scale grade). Observers assessed images twice, 2 weeks apart, using CEBuS (CEBuS-0 - no or minimal bubbles, covering<5% of the surface; CEBuS-1 - bubbles covering 5%-50%; CEBuS-2 - bubbles covering >50%) and reporting the clinical action (do nothing; wash with water; wash with simethicone). Results CEBuS provided high levels of agreement both in evaluation Phase 1 (4 experts) and Phase 2 (6 experts and 13 non-experts), with almost perfect intraobserver reliability: kappa 0.82 (95% confidence interval 0.75-0.88) and 0.86 (0.85-0.88); interobserver agreement - intraclass correlation coefficient (ICC) 0.83 (0.73-0.89) and 0.90 (0.86-0.94). Previous endoscopic experience had no influence on agreement among experts vs. non-experts: kappa 0.86 (0.80-0.91) vs. 0.87 (0.84-0.89) and ICC 0.91 (0.87-0.94) vs. 0.90 (0.86-0.94), respectively. Interobserver agreement on clinical action was ICC 0.63 (0.43-0.78) in Phase 1 and 0.77 (0.68-0.84) in Phase 2.Absolute agreement on clinical action per scale grade was 85% (82-88) for CEBuS-0, 21% (16-26) for CEBuS-1, and 74% (70-78) for CEBuS-2. Conclusion CEBuS proved to be a reliable instrument to standardize the evaluation of colonic bubbles during colonoscopy. Assessment in daily practice is warranted.
Lingua originaleEnglish
pagine (da-a)45-51
Numero di pagine7
RivistaEndoscopy
Volume54
DOI
Stato di pubblicazionePubblicato - 2022

Keywords

  • Colon Endoscopic Bubble Scale

Fingerprint

Entra nei temi di ricerca di 'The Colon Endoscopic Bubble Scale (CEBuS): A two-phase evaluation study'. Insieme formano una fingerprint unica.

Cita questo