TY - JOUR
T1 - Site- and house-specific and meteorological factors influencing exchange of particles between outdoor and indoor domestic environments
AU - Chiesa, Maria
AU - Urgnani, Rossella
AU - Marzuoli, Riccardo
AU - Finco, Angelo
AU - Gerosa, Giacomo Alessandro
PY - 2019
Y1 - 2019
N2 - The aim of this study was to investigate the influence of site- and house-specific as well as meteorological factors on indoor and outdoor particle concentrations. Particle number (PN) and particle mass (PM) concentrations were monitored in 62 houses in Brescia, Northern Italy, during two winter monitoring periods. Measurements were conducted in houses of non-smokers and without the activation of any internal aerosol sources from domestic activities such as cooking and cleaning. Indoor and outdoor particle concentrations were measured for 30 min in each house. A wide-range aerosol spectrometer (MINIWRAS 1371, GRIMM) was used to detect 41 classes of particles from 10 nm to 35 μm. The effects of natural ventilation on indoor particle concentrations were also considered by measuring PM and PN indoor/outdoor ratios before and after a window was opened for a period of 15 min. An ANOVA analysis was performed on a sub-dataset of 35 houses to evaluate the dependence of PN and PM concentrations on site- and house-specific as well as meteorological factors. The house energy class was significantly related to indoor particle concentrations, and window dimensions seemed to influence the concentrations both before and after the ventilation period. We found that some factors, e.g., the floor level, need further investigation.
AB - The aim of this study was to investigate the influence of site- and house-specific as well as meteorological factors on indoor and outdoor particle concentrations. Particle number (PN) and particle mass (PM) concentrations were monitored in 62 houses in Brescia, Northern Italy, during two winter monitoring periods. Measurements were conducted in houses of non-smokers and without the activation of any internal aerosol sources from domestic activities such as cooking and cleaning. Indoor and outdoor particle concentrations were measured for 30 min in each house. A wide-range aerosol spectrometer (MINIWRAS 1371, GRIMM) was used to detect 41 classes of particles from 10 nm to 35 μm. The effects of natural ventilation on indoor particle concentrations were also considered by measuring PM and PN indoor/outdoor ratios before and after a window was opened for a period of 15 min. An ANOVA analysis was performed on a sub-dataset of 35 houses to evaluate the dependence of PN and PM concentrations on site- and house-specific as well as meteorological factors. The house energy class was significantly related to indoor particle concentrations, and window dimensions seemed to influence the concentrations both before and after the ventilation period. We found that some factors, e.g., the floor level, need further investigation.
KW - ANOVA
KW - Domestic environments
KW - House-specific factors
KW - I/O ratio
KW - Particle mass
KW - Particles number
KW - ANOVA
KW - Domestic environments
KW - House-specific factors
KW - I/O ratio
KW - Particle mass
KW - Particles number
UR - http://hdl.handle.net/10807/142179
UR - http://www.elsevier.com/inca/publications/store/2/9/6/index.htt
U2 - 10.1016/j.buildenv.2019.106181
DO - 10.1016/j.buildenv.2019.106181
M3 - Article
SN - 0360-1323
VL - 160
SP - 106181-N/A
JO - Building and Environment
JF - Building and Environment
ER -