Abstract
We consider a simple version of a cyclic adiabatic inversion ͑CAI͒ technique in magnetic-resonance force\r\nmicroscopy ͑MRFM͒. We study the problem: What component of the spin is measured in the CAI MRFM? We\r\nshow that the nondestructive detection of the cantilever vibrations provides a measurement of the spin com-\r\nponent along the effective magnetic field. This result is based on numerical simulations of the Hamiltonian\r\n ̈\r\ndynamics ͑the Schrodinger equation͒ and the numerical solution of the master equation.
| Lingua originale | Inglese |
|---|---|
| pagine (da-a) | 094425-1-094425-6 |
| Numero di pagine | 6 |
| Rivista | Physical Review B - Condensed Matter and Materials Physics |
| Numero di pubblicazione | 67, 094425 |
| DOI | |
| Stato di pubblicazione | Pubblicato - 2003 |
All Science Journal Classification (ASJC) codes
- Materiali Elettronici, Ottici e Magnetici
- Fisica della Materia Condensata
Keywords
- quantum computer
- single spin measurement
Fingerprint
Entra nei temi di ricerca di '"Single spin measurement and decoherence in magnetic resonance force microscopy"'. Insieme formano una fingerprint unica.Cita questo
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver