Sensitivity Analysis of Single Beat Left Ventricular Elastance Estimation by Chen Method

  • Arianna Di Molfetta
  • , G. Ferrari
  • , V. Cusimano
  • , G. Di Ruzza
  • , P. Mollo
  • , D. Boncompagni
  • , M. Cesario
  • , C. Volponi
  • , Massimo Massetti
  • , M. Menichelli
  • , Maurizio Menichelli
  • Polish Academy of Sciences
  • IASI-Italian National Reserch Council
  • Ospedale F. Spaziani

Risultato della ricerca: Contributo in rivistaArticolo

Abstract

Introduction: Left ventricular (LV) end-systolic elastance (Ees) can be estimated using single-beat (Ees(sb)) Chen method, employing systolic and diastolic arm-cuff pressures, stroke volume (SV), ejection fraction and estimated normalized ventricular elastance at arterial end-diastole. This work aims to conduct a sensitivity analysis of Chen formula to verify its reliability and applicability in clinical scenario. Methods: Starting from a baseline condition, we evaluated the sensitivity of Ees(sb) to the parameters contained in the formula. Moreover, a mathematical model of the cardiovascular system was used to evaluate the sensitivity of Ees(sb) to end-diastolic LV elastance (Eed), Ees, arterial systemic resistance (Ras) and heart rate (HR). Results: In accordance with Ees definition, Ees(sb) increases by increasing aortic pressure and pre-ejection time, reaching the highest value for a pre-ejection time = 40 ms, and then decreases. In contrast with Ees definition, Ees(sb) increases (from 3.21 mmHg/mL to 12.15 mmHg/mL) by increasing the LV end-systolic volume and decreases by increasing the SV. In the majority of the analysis with the mathematical model, Ees was underestimated using the Chen method: by increasing Ees (from 0.5 to 2.5 mmHg/mL), Ees(sb) passes only from 0.56 to 1.54 mmHg/mL. Ees(sb) increases for higher Eed (from 1.03 to 2.33 mmHg/mL). Finally, Ees(sb) decreases (increases) for HR < 50 bpm (< 50 bpm), and for Ras < 1100 mmHg/gcm4 (> 1100 mmHg/gcm4). Conclusion: Unexpectedly Ees(sb) increases for higher LV end-systolic volume and decreases for higher SV. These results contrast with Ees definition, which is the ratio between the LV end-systolic pressure and the LV end-systolic volume. Moreover, Ees(sb) is influenced by cardiocirculatory parameters such as LV Eed, HR, Ras, ejection time, and pre-ejection time. Finally, Ees(sb) computed with the model output often underestimates model Ees.
Lingua originaleInglese
pagine (da-a)139-146
Numero di pagine8
RivistaCardiovascular Engineering and Technology
Volume13
DOI
Stato di pubblicazionePubblicato - 2022

Keywords

  • Chen
  • Echocardiography
  • Elastance
  • Pressure-volume loop
  • Single beat method

Fingerprint

Entra nei temi di ricerca di 'Sensitivity Analysis of Single Beat Left Ventricular Elastance Estimation by Chen Method'. Insieme formano una fingerprint unica.