TY - JOUR
T1 - Relation between conversion degree and cytotoxicity of a flowable bulk-fill and three conventional flowable resin-composites
AU - Marigo, Luca
AU - Spagnuolo, Gianrico
AU - Malara, Fortunato
AU - Martorana, Giuseppe Ettore
AU - Cordaro, Massimo
AU - Lupi, Alessandro
AU - Nocca, Giuseppina
PY - 2015
Y1 - 2015
N2 - OBJECTIVE:\r\nThe aim of this study is to evaluate if the cytotoxic effects of the Surefil SDR flow, bulk fill flowable composite resin and three conventional flowable materials (Venus Diamond Flow, Filtex Supreme XTE Flowable and Enamel plus HRi Flow) correlated with the conversion degree (DC); hardness and depth of cure are also assessed.\r\nMATERIALS AND METHODS:\r\nDisks of each materials - cured using LED lamp - are utilized to evaluate DC (by FT-IR technique), amount of leached monomers (by HPLC technique), hardness (by Vickers hardness tester) and cytotoxicity (by MTT test).\r\nRESULTS:\r\nAll tested materials show light cytotoxic effects, independently from DC values. Both the latter parameter and the hardness, in fact, change in function of thickness and type of material. HPLC results show that the monomers amount leached from each specimen is influenced by thickness but it is always very low which justifies the absence of any cytotoxic effect.\r\nCONCLUSIONS:\r\nOur findings suggest that there are not statistically significant differences in cytotoxicity in all experimental conditions, notwithstanding the differences in hardness and in degree of conversion.\r\nPMID: 26698240 [PubMed - in process]
AB - OBJECTIVE:\r\nThe aim of this study is to evaluate if the cytotoxic effects of the Surefil SDR flow, bulk fill flowable composite resin and three conventional flowable materials (Venus Diamond Flow, Filtex Supreme XTE Flowable and Enamel plus HRi Flow) correlated with the conversion degree (DC); hardness and depth of cure are also assessed.\r\nMATERIALS AND METHODS:\r\nDisks of each materials - cured using LED lamp - are utilized to evaluate DC (by FT-IR technique), amount of leached monomers (by HPLC technique), hardness (by Vickers hardness tester) and cytotoxicity (by MTT test).\r\nRESULTS:\r\nAll tested materials show light cytotoxic effects, independently from DC values. Both the latter parameter and the hardness, in fact, change in function of thickness and type of material. HPLC results show that the monomers amount leached from each specimen is influenced by thickness but it is always very low which justifies the absence of any cytotoxic effect.\r\nCONCLUSIONS:\r\nOur findings suggest that there are not statistically significant differences in cytotoxicity in all experimental conditions, notwithstanding the differences in hardness and in degree of conversion.\r\nPMID: 26698240 [PubMed - in process]
KW - Dental material
KW - Dental material
UR - https://publicatt.unicatt.it/handle/10807/69955
UR - https://www.scopus.com/inward/citedby.uri?partnerID=HzOxMe3b&scp=84966350792&origin=inward
UR - https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84966350792&origin=inward
M3 - Article
SN - 1128-3602
VL - 19
SP - 4469
EP - 4480
JO - European Review for Medical and Pharmacological Sciences
JF - European Review for Medical and Pharmacological Sciences
IS - 23
ER -