TY - JOUR
T1 - Rapid on-site evaluation of transbronchial aspirates in the diagnosis of hilar and mediastinal adenopathy: a randomized trial
AU - Trisolini, Rocco
AU - Cancellieri, Alessandra
AU - Tinelli, Carmine
AU - Paioli, Daniela
AU - Scudeller, Luigia
AU - Casadei, Gian Piero
AU - Parri, Sergio Forti
AU - Livi, Vanina
AU - Bondi, Arrigo
AU - Boaron, Maurizio
AU - Patelli, Marco
PY - 2011
Y1 - 2011
N2 - Background: Rapid on-site evaluation (ROSE) of transbronchial needle aspirates has long been used during flexible bronchoscopy, but its usefulness in the diagnosis of hilar and mediastinal adenopathy is controversial. The aim of the present study was to evaluate the extent to which ROSE can be valuable in patients undergoing transbronchial needle aspiration (TBNA) for the diagnosis of hilar and mediastinal adenopathy.Methods: A total of 168 consecutive patients with enlarged lymph nodes were randomized to undergo TBNA with or without ROSE. The primary outcome measure of the study was the diagnostic yield of TBNA on a per-patient basis. Secondary outcome measures included the percentage of adequate specimens on a per-lymph node basis, the number of biopsy sites on a per-patient basis, and the complication rate of bronchoscopy on a per-patient basis.Results: We found no significant difference between the TBNA group and the ROSE group in terms of diagnostic yield (75.3% vs 78.3%, respectively; P = .64), and percentage of adequate specimens (86.5% vs 78.4%, respectively; P = .11). The median (interquartile range) number of biopsy sites was significantly lower in the ROSE group (1 [1-2] vs 2 [1-2], respectively; P = .0005). The complication rate of bronchoscopy was significantly lower in patients undergoing on-site review (6% vs 20%; P = .01), whereas the complication rate of TBNA was similar among the study groups.Conclusions: ROSE of transbronchial aspirates from hilar and mediastinal nodes enables avoidance of additional biopsy without loss in diagnostic yield and reduces the complication rate of bronchoscopy. Trial registry: ClinicalTrials.gov; No.: NCT00915330; URL: www.clinicaltrials.gov CHEST 2011;139(2):395-401
AB - Background: Rapid on-site evaluation (ROSE) of transbronchial needle aspirates has long been used during flexible bronchoscopy, but its usefulness in the diagnosis of hilar and mediastinal adenopathy is controversial. The aim of the present study was to evaluate the extent to which ROSE can be valuable in patients undergoing transbronchial needle aspiration (TBNA) for the diagnosis of hilar and mediastinal adenopathy.Methods: A total of 168 consecutive patients with enlarged lymph nodes were randomized to undergo TBNA with or without ROSE. The primary outcome measure of the study was the diagnostic yield of TBNA on a per-patient basis. Secondary outcome measures included the percentage of adequate specimens on a per-lymph node basis, the number of biopsy sites on a per-patient basis, and the complication rate of bronchoscopy on a per-patient basis.Results: We found no significant difference between the TBNA group and the ROSE group in terms of diagnostic yield (75.3% vs 78.3%, respectively; P = .64), and percentage of adequate specimens (86.5% vs 78.4%, respectively; P = .11). The median (interquartile range) number of biopsy sites was significantly lower in the ROSE group (1 [1-2] vs 2 [1-2], respectively; P = .0005). The complication rate of bronchoscopy was significantly lower in patients undergoing on-site review (6% vs 20%; P = .01), whereas the complication rate of TBNA was similar among the study groups.Conclusions: ROSE of transbronchial aspirates from hilar and mediastinal nodes enables avoidance of additional biopsy without loss in diagnostic yield and reduces the complication rate of bronchoscopy. Trial registry: ClinicalTrials.gov; No.: NCT00915330; URL: www.clinicaltrials.gov CHEST 2011;139(2):395-401
KW - hilar and mediastinal adenopathy
KW - hilar and mediastinal adenopathy
UR - http://hdl.handle.net/10807/282198
U2 - 10.1378/chest.10-1521
DO - 10.1378/chest.10-1521
M3 - Article
SN - 1931-3543
VL - 139
SP - 395
EP - 401
JO - Chest
JF - Chest