TY - JOUR
T1 - Processed Electroencephalogram-Based Monitoring to Guide Sedation in Critically Ill Adult Patients: Recommendations from an International Expert Panel-Based Consensus
AU - Rasulo, FA
AU - Hopkins, P
AU - Lobo, FA
AU - Pandin, P
AU - Matta, B
AU - Carozzi, C
AU - Romagnoli, S
AU - Absalom, A
AU - Badenes, R
AU - Bleck, T
AU - Caricato, Anselmo
AU - Claassen, J
AU - Denault, A
AU - Honorato, C
AU - Motta, S
AU - Meyfroidt, G
AU - Radtke, FM
AU - Ricci, Z
AU - Robba, C
AU - Taccone, FS
AU - Vespa, P
AU - Nardiello, I
AU - Lamperti, M
PY - 2023
Y1 - 2023
N2 - Background The use of processed electroencephalography (pEEG) for depth of sedation (DOS) monitoring is increasing in anesthesia; however, how to use of this type of monitoring for critical care adult patients within the intensive care unit (ICU) remains unclear. Methods A multidisciplinary panel of international experts consisting of 21 clinicians involved in monitoring DOS in ICU patients was carefully selected on the basis of their expertise in neurocritical care and neuroanesthesiology. Panelists were assigned four domains (techniques for electroencephalography [EEG] monitoring, patient selection, use of the EEG monitors, competency, and training the principles of pEEG monitoring) from which a list of questions and statements was created to be addressed. A Delphi method based on iterative approach was used to produce the final statements. Statements were classified as highly appropriate or highly inappropriate (median rating >= 8), appropriate (median rating >= 7 but < 8), or uncertain (median rating < 7) and with a strong disagreement index (DI) (DI < 0.5) or weak DI (DI >= 0.5 but < 1) consensus. Results According to the statements evaluated by the panel, frontal pEEG (which includes a continuous colored density spectrogram) has been considered adequate to monitor the level of sedation (strong consensus), and it is recommended by the panel that all sedated patients (paralyzed or nonparalyzed) unfit for clinical evaluation would benefit from DOS monitoring (strong consensus) after a specific training program has been performed by the ICU staff. To cover the gap between knowledge/rational and routine application, some barriers must be broken, including lack of knowledge, validation for prolonged sedation, standardization between monitors based on different EEG analysis algorithms, and economic issues. Conclusions Evidence on using DOS monitors in ICU is still scarce, and further research is required to better define the benefits of using pEEG. This consensus highlights that some critically ill patients may benefit from this type of neuromonitoring.
AB - Background The use of processed electroencephalography (pEEG) for depth of sedation (DOS) monitoring is increasing in anesthesia; however, how to use of this type of monitoring for critical care adult patients within the intensive care unit (ICU) remains unclear. Methods A multidisciplinary panel of international experts consisting of 21 clinicians involved in monitoring DOS in ICU patients was carefully selected on the basis of their expertise in neurocritical care and neuroanesthesiology. Panelists were assigned four domains (techniques for electroencephalography [EEG] monitoring, patient selection, use of the EEG monitors, competency, and training the principles of pEEG monitoring) from which a list of questions and statements was created to be addressed. A Delphi method based on iterative approach was used to produce the final statements. Statements were classified as highly appropriate or highly inappropriate (median rating >= 8), appropriate (median rating >= 7 but < 8), or uncertain (median rating < 7) and with a strong disagreement index (DI) (DI < 0.5) or weak DI (DI >= 0.5 but < 1) consensus. Results According to the statements evaluated by the panel, frontal pEEG (which includes a continuous colored density spectrogram) has been considered adequate to monitor the level of sedation (strong consensus), and it is recommended by the panel that all sedated patients (paralyzed or nonparalyzed) unfit for clinical evaluation would benefit from DOS monitoring (strong consensus) after a specific training program has been performed by the ICU staff. To cover the gap between knowledge/rational and routine application, some barriers must be broken, including lack of knowledge, validation for prolonged sedation, standardization between monitors based on different EEG analysis algorithms, and economic issues. Conclusions Evidence on using DOS monitors in ICU is still scarce, and further research is required to better define the benefits of using pEEG. This consensus highlights that some critically ill patients may benefit from this type of neuromonitoring.
KW - Consensus
KW - Critically ill
KW - EEG
KW - Monitoring
KW - Sedation
KW - Consensus
KW - Critically ill
KW - EEG
KW - Monitoring
KW - Sedation
UR - https://publicatt.unicatt.it/handle/10807/304352
UR - https://www.scopus.com/inward/citedby.uri?partnerID=HzOxMe3b&scp=85135251349&origin=inward
UR - https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85135251349&origin=inward
U2 - 10.1007/s12028-022-01565-5
DO - 10.1007/s12028-022-01565-5
M3 - Article
SN - 1541-6933
VL - 38
SP - 296
EP - 311
JO - Neurocritical Care
JF - Neurocritical Care
IS - 2
ER -