TY - JOUR
T1 - Posterior Cranial Fossa Surgery with a 3 Dimensional Exoscope: A Single-Center Survey-Based Analysis and a Literature Review
AU - Mattogno, Pier Paolo
AU - Della Pepa, Giuseppe Maria
AU - Menna, Grazia
AU - Agostini, Ludovico
AU - Albanese, Alessio
AU - Tamburrini, Gianpiero
AU - Gaudino, Simona
AU - Olivi, Alessandro
AU - Doglietto, Francesco
PY - 2024
Y1 - 2024
N2 - Objective: The potential advantages of exoscopy have been discussed theoretically for a long time. Such a concept holds significance, especially in the specific setting of the posterior cranial fossa (PCF), characterized by complex anatomy and long and narrow surgical corridors with relatively extreme working angles. We aimed to: 1) analyze the institutional preliminary case-based data on the use of the Robotic 3D Exoscope AEOS Aesculap in three different PCF approaches: retrosigmoid (RSA), midline suboccipital (MSA), and supracerebellar infratentorial via feedbacks was collected using a 20-point questionnaire, and 2) perform a comprehensive review of the literature concerning the use of EX in PCF surgery. Results: A total of 38 patients with neurosurgical pathologies underwent a neurosurgical procedure using the EX (Robotic 3D exoscope AEOS Aesculap) at our institution between January and March 2022. 21 surgeons were involved in the abovementioned PCF surgeries and answered the questionnaire. The main perceived advantages were in terms of ergonomics (67%), magnification (52%), and visualization of extreme angles. The main reported disadvantage was color vision (16, 76%), followed by manual mobility (24%). Concerning the review, the search of the literature yielded a total of 177 results. Upon full-text review, 17 articles were included, including 153 patients. Conclusions: In conclusion, our study provides a comprehensive evaluation of the advantages and challenges associated with using the exoscope in posterior fossa surgery, setting a precedent as the first to report on a questionnaire-based analysis of exoscope utilization in this specific domain.
AB - Objective: The potential advantages of exoscopy have been discussed theoretically for a long time. Such a concept holds significance, especially in the specific setting of the posterior cranial fossa (PCF), characterized by complex anatomy and long and narrow surgical corridors with relatively extreme working angles. We aimed to: 1) analyze the institutional preliminary case-based data on the use of the Robotic 3D Exoscope AEOS Aesculap in three different PCF approaches: retrosigmoid (RSA), midline suboccipital (MSA), and supracerebellar infratentorial via feedbacks was collected using a 20-point questionnaire, and 2) perform a comprehensive review of the literature concerning the use of EX in PCF surgery. Results: A total of 38 patients with neurosurgical pathologies underwent a neurosurgical procedure using the EX (Robotic 3D exoscope AEOS Aesculap) at our institution between January and March 2022. 21 surgeons were involved in the abovementioned PCF surgeries and answered the questionnaire. The main perceived advantages were in terms of ergonomics (67%), magnification (52%), and visualization of extreme angles. The main reported disadvantage was color vision (16, 76%), followed by manual mobility (24%). Concerning the review, the search of the literature yielded a total of 177 results. Upon full-text review, 17 articles were included, including 153 patients. Conclusions: In conclusion, our study provides a comprehensive evaluation of the advantages and challenges associated with using the exoscope in posterior fossa surgery, setting a precedent as the first to report on a questionnaire-based analysis of exoscope utilization in this specific domain.
KW - Ergornomics
KW - Exoscope
KW - Posterior cranial fossa
KW - Training
KW - Ergornomics
KW - Exoscope
KW - Posterior cranial fossa
KW - Training
UR - http://hdl.handle.net/10807/304218
U2 - 10.1016/j.wneu.2024.05.012
DO - 10.1016/j.wneu.2024.05.012
M3 - Article
SN - 1878-8750
VL - 189
SP - e15-e26
JO - World Neurosurgery
JF - World Neurosurgery
ER -