TY - JOUR
T1 - PCR experion automated electrophoresis system to detect Lysteria monocytogenes in food.
AU - Delibato, Elisabetta
AU - Gattuso, Antonietta
AU - Minucci, Angelo
AU - Auricchio, Bruna
AU - De Medici, Dario
AU - Toti, Laura
AU - Castagnola, Massimo
AU - Capoluongo, Ettore Domenico
AU - Gianfranceschi, Monica Virginia
PY - 2009
Y1 - 2009
N2 - Listeria monocytogenes is frequently found as a contaminant in raw and ready-to-eat foods. The ability of L. monocytogenes to multiply at refrigeration temperatures and to grow in a wide range of pH values is of particular concern for food safety. According to the European Union regulation on microbiological criteria for foodstuffs, L. monocytogenes must be absent in some categories of ready-to-eat foods. The standard microbiological method for L. monocytogenes detection in foods (ISO 11290-1: 1996 (ISO, International Organization for Standardization)) is cost and time consuming. Developments of rapid, cost-effective and automated diagnostic methods to detect food-borne pathogens in foods continue to be a major concern for the industry and public health. The aim of this study was the development of a rapid, sensitive and specific molecular detection method for L. monocytogenes. To this purpose, we have applied a capillary electrophoresis method to a PCR protocol (PCR-EES (EES, experion automated electrophoresis system)) for detecting L. monocytogenes in food. In particular, a microfluidic chip-based automated electrophoresis system (experion automated electrophoresis system, Bio-Rad Laboratories, USA) was used for the rapid and automatic analysis of the amplicons. Fifty naturally contaminated samples were analysed with this method and the results were compared with those obtained with ISO method. Moreover, the microfluidic chip-based automated electrophoresis system was compared with classical gel electrophoresis (PCR-CGE). The results showed that after 24 h of culture enrichment, the PCR-EES showed a relative accuracy of 100% with ISO, while using PCR-CGE decreased it down to 96%. After 48 h of enrichment, both PCR-EES and PCR-CGE showed an accuracy of 100% with ISO.
AB - Listeria monocytogenes is frequently found as a contaminant in raw and ready-to-eat foods. The ability of L. monocytogenes to multiply at refrigeration temperatures and to grow in a wide range of pH values is of particular concern for food safety. According to the European Union regulation on microbiological criteria for foodstuffs, L. monocytogenes must be absent in some categories of ready-to-eat foods. The standard microbiological method for L. monocytogenes detection in foods (ISO 11290-1: 1996 (ISO, International Organization for Standardization)) is cost and time consuming. Developments of rapid, cost-effective and automated diagnostic methods to detect food-borne pathogens in foods continue to be a major concern for the industry and public health. The aim of this study was the development of a rapid, sensitive and specific molecular detection method for L. monocytogenes. To this purpose, we have applied a capillary electrophoresis method to a PCR protocol (PCR-EES (EES, experion automated electrophoresis system)) for detecting L. monocytogenes in food. In particular, a microfluidic chip-based automated electrophoresis system (experion automated electrophoresis system, Bio-Rad Laboratories, USA) was used for the rapid and automatic analysis of the amplicons. Fifty naturally contaminated samples were analysed with this method and the results were compared with those obtained with ISO method. Moreover, the microfluidic chip-based automated electrophoresis system was compared with classical gel electrophoresis (PCR-CGE). The results showed that after 24 h of culture enrichment, the PCR-EES showed a relative accuracy of 100% with ISO, while using PCR-CGE decreased it down to 96%. After 48 h of enrichment, both PCR-EES and PCR-CGE showed an accuracy of 100% with ISO.
KW - PCR
KW - electrophoresis
KW - monocytogenes
KW - PCR
KW - electrophoresis
KW - monocytogenes
UR - http://hdl.handle.net/10807/26101
M3 - Article
SN - 1615-9306
SP - 3817
EP - 3821
JO - Journal of Separation Science
JF - Journal of Separation Science
ER -