Magnetocardiographic Pacemapping For Non-Fluoroscopic Localization Of Intracardiac Electrophysiology Catheters

Riccardo Fenici, K Pesola, P Korhonen, M Makijarvi, J Nenonen, L Toivonen, T. Katila

Risultato della ricerca: Contributo in rivistaArticolo in rivistapeer review

20 Citazioni (Scopus)

Abstract

The purpose of the study was to validate, in patients, the accuracy of magnetocardiography (MCG) for three-dimensional localization of an amagnetic catheter (AC) for multiple monophasic action potential (MAP) with a spatial resolution of 4 mm2. The AC was inserted in five patients after routine electrophysiological study. Four MAPs were simultaneously recorded to monitor the stability of endocardial contact of the AC during the MCG localization. MAP signals were band-pass filtered DC-500 Hz and digitized at 2 KHz. The position of the AC was also imaged by biplane fluoroscopy (XR), along with lead markers. MCG studies were performed with a multichannel SQUID system in the Helsinki BioMag shielded room. Current dipoles (5 mm; 10 mA), activated at the tip of the AC, were localized using the equivalent current dipole (ECD) model in patient-specific boundary element torso. The accuracy of the MCG localizations was evaluated by: (1) anatomic location of ECD in the MRI, (2) mismatch with XR. The AC was correctly localized in the right ventricle of all patients using MRI. The mean three-dimensional mismatch between XR and MCG localizations was 6 +/- 2 mm (beat-to-beat analysis). The co efficient of variation of three-dimensional localization of the AC was 1.37% and the coefficient of reproducibility was 2.6 mm. In patients, in the absence of arrhythmias, average local variation coefficients of right ventricular MAP duration at 50% and 90% of repolarization, were 7.4% and 3.1%, respectively. This study demonstrates that with adequate signal-to-noise ratio, MCG three-dimensional localizations are accurate and reproducible enough to provide nonfluoroscopy dependant multimodal imaging for high resolution endocardial mapping of monophasic action potentials.
Lingua originaleEnglish
pagine (da-a)2492-2499
Numero di pagine8
RivistaPACING AND CLINICAL ELECTROPHYSIOLOGY
Volume21
Stato di pubblicazionePubblicato - 1998
Pubblicato esternamente

Keywords

  • Electrophysiology Catheters
  • Magnetocardiographic Pacemapping

Fingerprint

Entra nei temi di ricerca di 'Magnetocardiographic Pacemapping For Non-Fluoroscopic Localization Of Intracardiac Electrophysiology Catheters'. Insieme formano una fingerprint unica.

Cita questo