TY - JOUR
T1 - Liver Stiffness in Pediatric Patients with Fatty Liver Disease: Diagnostic Accuracy and Reproducibility of Shear-Wave Elastography
AU - Garcovich, Matteo
AU - Veraldi, Silvio
AU - Di Stasio, Enrico
AU - Zocco, Maria Assunta
AU - Monti, Lidia
AU - Tomà, Paolo
AU - Pompili, Maurizio
AU - Gasbarrini, Antonio
AU - Nobili, Valerio
PY - 2017
Y1 - 2017
N2 - Purpose To evaluate the diagnostic accuracy of shear-wave elastography (SWE) in identifying different degrees of fibrosis in a cohort of consecutive children and adolescents with nonalcoholic steatohepatitis (NASH). Materials and Methods Consecutive pediatric patients scheduled to undergo liver biopsy were studied with an ultrasonography-based SWE system. Elastography was performed in 68 of 69 patients with biopsy-proved NASH (37 boys and 31 girls; mean age, 12.6 years ± 2.48; age range, 8-17 years). The correlations among laboratory findings, liver stiffness, and fibrosis score were analyzed, and the area under the receiver operating characteristic curve (AUC) was used to assess the presence of any fibrosis (score ≥F1) or significant fibrosis (score ≥F2). Findings from histologic examination were used as the standard of reference. Results SWE showed a very high correlation with liver fibrosis (P < .001) at univariate and multivariate analyses. The AUCs for the association of any and significant fibrosis were 0.92 (95% confidence interval [CI]: 0.86, 0.98) and 0.97 (95% CI: 0.95, 0.99), respectively. The intraclass correlation coefficient for absolute agreement was 0.95 (95% CI: 0.90, 0.97). Conclusion SWE is an accurate and reproducible noninvasive technique that efficiently depicts the presence of significant liver fibrosis and, less accurately, mild liver fibrosis in pediatric patients with nonalcoholic fatty liver disease. Larger clinical prospective studies are warranted to confirm SWE accuracy and establish threshold values for fibrosis grading in comparison or in combination with other noninvasive methods. © RSNA, 2016
AB - Purpose To evaluate the diagnostic accuracy of shear-wave elastography (SWE) in identifying different degrees of fibrosis in a cohort of consecutive children and adolescents with nonalcoholic steatohepatitis (NASH). Materials and Methods Consecutive pediatric patients scheduled to undergo liver biopsy were studied with an ultrasonography-based SWE system. Elastography was performed in 68 of 69 patients with biopsy-proved NASH (37 boys and 31 girls; mean age, 12.6 years ± 2.48; age range, 8-17 years). The correlations among laboratory findings, liver stiffness, and fibrosis score were analyzed, and the area under the receiver operating characteristic curve (AUC) was used to assess the presence of any fibrosis (score ≥F1) or significant fibrosis (score ≥F2). Findings from histologic examination were used as the standard of reference. Results SWE showed a very high correlation with liver fibrosis (P < .001) at univariate and multivariate analyses. The AUCs for the association of any and significant fibrosis were 0.92 (95% confidence interval [CI]: 0.86, 0.98) and 0.97 (95% CI: 0.95, 0.99), respectively. The intraclass correlation coefficient for absolute agreement was 0.95 (95% CI: 0.90, 0.97). Conclusion SWE is an accurate and reproducible noninvasive technique that efficiently depicts the presence of significant liver fibrosis and, less accurately, mild liver fibrosis in pediatric patients with nonalcoholic fatty liver disease. Larger clinical prospective studies are warranted to confirm SWE accuracy and establish threshold values for fibrosis grading in comparison or in combination with other noninvasive methods. © RSNA, 2016
KW - liver, pediatric patients, fatty liver disease
KW - liver, pediatric patients, fatty liver disease
UR - http://hdl.handle.net/10807/92883
U2 - 10.1148/radiol.2016161002
DO - 10.1148/radiol.2016161002
M3 - Article
SN - 0033-8419
VL - 283
SP - 820
EP - 827
JO - Radiology
JF - Radiology
ER -