T1 - Is the New Infant Jarvik 2015 Suitable for Patients<8 kg? In Vitro Study Using a Hybrid Simulator
AU - Di Molfetta, Arianna
AU - Zielinski, Krzysztof
AU - Ferrari, Gianfranco
AU - Kozarski, Macej
AU - Okrzeja, Piotr
AU - Iacobelli, Roberta
AU - Filippelli, Sergio
AU - Perri, Gianluigi
AU - Darowski, Marek
AU - Massetti, Massimo
AU - Jarvik, Robert
AU - Amodeo, Antonio
PY - 2019
Y1 - 2019
N2 - Our aim was to study the feasibility of implanting the Infant Jarvik 2015 in patients weighing less than 8 kg. The Infant Jarvik 2015 left ventricular assist device (LVAD) was tested in a hybrid simulator of the cardiovascular system reproducing specific patients’ hemodynamics for different patient weights (2–7 kg). For each weight, the sensitivity of the pump to different circulatory parameters (peripheral resistance, left ventricular elastance, right ventricular elastance, heart rate, and heart filling characteristics) has been tested repeating for each experiment a pump ramp (10 000–18 000 rpm). The increase in the pump speed causes a decrease (increase) in the left (right) atrial pressure, an increase (decrease) in the arterial systemic (pulmonary) pressure, an increase in the right ventricular pressure, a decrease (increase) in the left (right) ventricular volume, a decrease in the left ventricular cardiac output, an increase in the LVAD output and an increase in the right ventricular cardiac output (total cardiac output). Suction was observed for lower weight patients and for higher pump speed in the case of vasodilation, left ventricular recovery, bradycardia, right ventricular failure, and left ventricular hypertrophy. Backflow was observed in the case of left ventricular recovery at lower pump speed. In the hybrid simulator, the Infant Jarvik 2015 could be suitable for the implantation in patients lower than 8 kg because of the stability of the device respect to the cardio/circulatory changes (low frequency of suction and backflow) and because of the capability of the device to maintain adequate patient hemodynamics.
AB - Our aim was to study the feasibility of implanting the Infant Jarvik 2015 in patients weighing less than 8 kg. The Infant Jarvik 2015 left ventricular assist device (LVAD) was tested in a hybrid simulator of the cardiovascular system reproducing specific patients’ hemodynamics for different patient weights (2–7 kg). For each weight, the sensitivity of the pump to different circulatory parameters (peripheral resistance, left ventricular elastance, right ventricular elastance, heart rate, and heart filling characteristics) has been tested repeating for each experiment a pump ramp (10 000–18 000 rpm). The increase in the pump speed causes a decrease (increase) in the left (right) atrial pressure, an increase (decrease) in the arterial systemic (pulmonary) pressure, an increase in the right ventricular pressure, a decrease (increase) in the left (right) ventricular volume, a decrease in the left ventricular cardiac output, an increase in the LVAD output and an increase in the right ventricular cardiac output (total cardiac output). Suction was observed for lower weight patients and for higher pump speed in the case of vasodilation, left ventricular recovery, bradycardia, right ventricular failure, and left ventricular hypertrophy. Backflow was observed in the case of left ventricular recovery at lower pump speed. In the hybrid simulator, the Infant Jarvik 2015 could be suitable for the implantation in patients lower than 8 kg because of the stability of the device respect to the cardio/circulatory changes (low frequency of suction and backflow) and because of the capability of the device to maintain adequate patient hemodynamics.
KW - Bioengineering
KW - Biomaterials
KW - Biomedical Engineering
KW - Hybrid model
KW - Infant Jarvik 2015
KW - Lumped parameter models
KW - Medicine (miscellaneous)
KW - Pediatric
KW - Ventricular assist device
KW - Bioengineering
KW - Biomaterials
KW - Biomedical Engineering
KW - Hybrid model
KW - Infant Jarvik 2015
KW - Lumped parameter models
KW - Medicine (miscellaneous)
KW - Pediatric
KW - Ventricular assist device
UR - http://hdl.handle.net/10807/130561
UR - http://onlinelibrary.wiley.com/journal/10.1111/(issn)1525-1594
U2 - 10.1111/aor.13302
DO - 10.1111/aor.13302
M3 - Article
SN - 0160-564X
VL - 43
SP - E1-E8
JO - Artificial Organs
JF - Artificial Organs
ER -