TY - JOUR
T1 - Internal Tube Occlusion with An Easily Removable Non-Absorbable Double Suture: A Novel Surgical Technique Adjunct for Non-Valved Glaucoma Drainage Devices
AU - Savastano, A.
AU - Gambini, Gloria
AU - Savastano, Maria Cristina
AU - Carlà, M. M.
AU - Rizzo, C.
AU - Caporossi, Tomaso
AU - Crincoli, Emanuele
AU - Rizzo, Stanislao
PY - 2023
Y1 - 2023
N2 - : To describe a surgical variant for non-valved glaucoma drainage device implants using an easily removable non-absorbable double suture into the lumen of the tube. A retrospective, non-comparative case series of 10 patients who underwent a non-valved glaucoma drainage device implant with an endoluminal double-suture for refractory glaucoma. The sutures were easily removed postoperatively without the need for an operating room. Intraocular pressure, number of medications, and early and late complications were evaluated with a follow-up of 12 months. None of the eyes that underwent an operation developed early or late complications. The first endoluminal suture was removed in all eyes with a mean time of removal of 30 ± 7 days. The second suture was removed in all eyes with a mean time of removal of 90 ± 7 days. No complications were noted, either, after or during suture removal. The mean preoperative IOP was 27.3 ± 4.0 and the postoperative IOP, at the end of the follow-up, was 12.7 ± 1.4. At the end of the follow-up, six patients (60%) achieved complete success and four patients (40%) achieved qualified success. In conclusion, in our case series, the surgical variant allowed for a safe and gradual regulation of the flow during postoperative management. Considering the efficacy of non-valved glaucoma drainage devices, an improvement in the safety profile allows surgeons to broaden the surgical indications.
AB - : To describe a surgical variant for non-valved glaucoma drainage device implants using an easily removable non-absorbable double suture into the lumen of the tube. A retrospective, non-comparative case series of 10 patients who underwent a non-valved glaucoma drainage device implant with an endoluminal double-suture for refractory glaucoma. The sutures were easily removed postoperatively without the need for an operating room. Intraocular pressure, number of medications, and early and late complications were evaluated with a follow-up of 12 months. None of the eyes that underwent an operation developed early or late complications. The first endoluminal suture was removed in all eyes with a mean time of removal of 30 ± 7 days. The second suture was removed in all eyes with a mean time of removal of 90 ± 7 days. No complications were noted, either, after or during suture removal. The mean preoperative IOP was 27.3 ± 4.0 and the postoperative IOP, at the end of the follow-up, was 12.7 ± 1.4. At the end of the follow-up, six patients (60%) achieved complete success and four patients (40%) achieved qualified success. In conclusion, in our case series, the surgical variant allowed for a safe and gradual regulation of the flow during postoperative management. Considering the efficacy of non-valved glaucoma drainage devices, an improvement in the safety profile allows surgeons to broaden the surgical indications.
KW - Baerveldt
KW - drainage device
KW - glaucoma
KW - glaucoma surgery
KW - long tube
KW - Baerveldt
KW - drainage device
KW - glaucoma
KW - glaucoma surgery
KW - long tube
UR - https://publicatt.unicatt.it/handle/10807/238414
UR - https://www.scopus.com/inward/citedby.uri?partnerID=HzOxMe3b&scp=85151069352&origin=inward
UR - https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85151069352&origin=inward
U2 - 10.3390/vision7010014
DO - 10.3390/vision7010014
M3 - Article
SN - 2411-5150
VL - 7
SP - 14
EP - 14
JO - VISION
JF - VISION
IS - 1
ER -