TY - JOUR
T1 - Interlocking circumareolar suture with undyed polyamide thread: a personal experience
AU - Salgarello, Marzia
AU - Visconti, Giuseppe
AU - Barone Adesi, Liliana
PY - 2013
Y1 - 2013
N2 - In plastic breast surgery, the interlocking areolar suture has gained wide popularity since its introduction in 2007 by Hammond and colleagues. The interlocking circumareolar suture plays its role in the setting of circumareolar excisions to achieve a durable areola shaping and to prevent scar widening/hypertrophy and areola spreading/distortion. This study retrospectively reviewed 49 breasts that underwent interlocking suture after July 2011 for both aesthetic and reconstructive indications. For the suturing, 3-0 undyed polyamide thread with a straight cutting needle (Dafilon; B. Braun Melsungen AG, Melsungen, Germany) was used. This suture material was preferred to Gore-Tex reported by Hammond and colleagues because it is undyed without any microporous configuration, more wieldy, and less expensive. All 49 breasts showed good results in terms of areola shaping and diameter control as well as good scar quality during a mean follow-up period of 12 months (range 2-18 months) (Fig. 2). No infection, suture extrusion, skin fistula, or granuloma were experienced. The suture was not visible at all, and the patients did not report its palpability. However, at careful examination, the thread resulted slightly palpable.
AB - In plastic breast surgery, the interlocking areolar suture has gained wide popularity since its introduction in 2007 by Hammond and colleagues. The interlocking circumareolar suture plays its role in the setting of circumareolar excisions to achieve a durable areola shaping and to prevent scar widening/hypertrophy and areola spreading/distortion. This study retrospectively reviewed 49 breasts that underwent interlocking suture after July 2011 for both aesthetic and reconstructive indications. For the suturing, 3-0 undyed polyamide thread with a straight cutting needle (Dafilon; B. Braun Melsungen AG, Melsungen, Germany) was used. This suture material was preferred to Gore-Tex reported by Hammond and colleagues because it is undyed without any microporous configuration, more wieldy, and less expensive. All 49 breasts showed good results in terms of areola shaping and diameter control as well as good scar quality during a mean follow-up period of 12 months (range 2-18 months) (Fig. 2). No infection, suture extrusion, skin fistula, or granuloma were experienced. The suture was not visible at all, and the patients did not report its palpability. However, at careful examination, the thread resulted slightly palpable.
KW - interlocking suture
KW - mastopexy
KW - interlocking suture
KW - mastopexy
UR - http://hdl.handle.net/10807/57132
U2 - 10.1007/s00266-013-0186-1
DO - 10.1007/s00266-013-0186-1
M3 - Article
SN - 0364-216X
VL - 37
SP - 1061
EP - 1062
JO - Aesthetic Plastic Surgery
JF - Aesthetic Plastic Surgery
ER -