TY - JOUR
T1 - Improved Patient Recovery With Minimally Invasive Aortic Valve Surgery: A Propensity-Matched Study
AU - Bruno, Piergiorgio
AU - Cammertoni, Federico
AU - Rosenhek, Raphael
AU - Mazza, Andrea
AU - Pavone, Natalia
AU - Iafrancesco, Mauro
AU - Nesta, Marialisa
AU - Chiariello, Giovanni Alfonso
AU - Spalletta, Claudio
AU - Graziano, Giovanni
AU - Sanesi, Valerio
AU - D’Errico, Denise
AU - Massetti, Massimo
PY - 2019
Y1 - 2019
N2 - Objective: Despite conflicting evidence available, minimally invasive aortic valve replacement (MIAVR) is increasingly used as an alternative to full sternotomy. We sought to compare early outcomes of aortic valve replacement through a full sternotomy (conventional aortic valve replacement [CAVR]) and upper ministernotomy (MIAVR). Methods: We analyzed 297 patients having undergone primary, elective, isolated MIAVR or CAVR between January 2014 and June 2018. Following propensity score matching, 120 patients remained in each group. Results: MIAVR required longer bypass (93 ± 26 vs 81 ± 24 minutes, P < 0.01) and operative times (214 ± 39 vs 182 ± 37 minutes, P < 0.01). However, aortic cross-clamp times were comparable (57 ± 17 vs 54 ± 14 minutes for MIAVR and CAVR, respectively, P = 0.14). MIAVR had less 24-hour blood loss (253 ± 204 vs 323 ± 296 mL, P = 0.03), less red blood cells transfusions [1.4 packs (1.1 o 1.9) vs 2.1 packs (1.8 to 2.7), P = 0.01], and shorter assisted ventilation time (7.1 ± 3.3 vs 9.7 ± 3.8 hours, P < 0.01) when compared to CAVR. These results led to significantly shorter intensive care unit and hospital stays for MIAVR patients (2.5 ± 1.3 vs 3.4 ± 1.1 days, P < 0.01 and 6.9 ± 4.1 vs 8.2 ± 4.8 days, P = 0.03, respectively). Thirty-day mortality and clinical outcomes did not differ significantly among groups. Conclusions: MIAVR through upper ministernotomy was shown to be as safe and reliable as CAVR. Patient recovery time was improved by shortening mechanical ventilation and reducing blood loss and transfusions. These results may be significant for high-risk patients undergoing aortic valve surgery.
AB - Objective: Despite conflicting evidence available, minimally invasive aortic valve replacement (MIAVR) is increasingly used as an alternative to full sternotomy. We sought to compare early outcomes of aortic valve replacement through a full sternotomy (conventional aortic valve replacement [CAVR]) and upper ministernotomy (MIAVR). Methods: We analyzed 297 patients having undergone primary, elective, isolated MIAVR or CAVR between January 2014 and June 2018. Following propensity score matching, 120 patients remained in each group. Results: MIAVR required longer bypass (93 ± 26 vs 81 ± 24 minutes, P < 0.01) and operative times (214 ± 39 vs 182 ± 37 minutes, P < 0.01). However, aortic cross-clamp times were comparable (57 ± 17 vs 54 ± 14 minutes for MIAVR and CAVR, respectively, P = 0.14). MIAVR had less 24-hour blood loss (253 ± 204 vs 323 ± 296 mL, P = 0.03), less red blood cells transfusions [1.4 packs (1.1 o 1.9) vs 2.1 packs (1.8 to 2.7), P = 0.01], and shorter assisted ventilation time (7.1 ± 3.3 vs 9.7 ± 3.8 hours, P < 0.01) when compared to CAVR. These results led to significantly shorter intensive care unit and hospital stays for MIAVR patients (2.5 ± 1.3 vs 3.4 ± 1.1 days, P < 0.01 and 6.9 ± 4.1 vs 8.2 ± 4.8 days, P = 0.03, respectively). Thirty-day mortality and clinical outcomes did not differ significantly among groups. Conclusions: MIAVR through upper ministernotomy was shown to be as safe and reliable as CAVR. Patient recovery time was improved by shortening mechanical ventilation and reducing blood loss and transfusions. These results may be significant for high-risk patients undergoing aortic valve surgery.
KW - aortic valve replacement
KW - minimally invasive
KW - upper ministernotomy
KW - aortic valve replacement
KW - minimally invasive
KW - upper ministernotomy
UR - http://hdl.handle.net/10807/146205
UR - https://in.sagepub.com/en-in/sas/press/sage-publishing-welcomes-innovations-technology-and-techniques-in-cardiothoracic-and-vascular
U2 - 10.1177/1556984519868715
DO - 10.1177/1556984519868715
M3 - Article
SN - 1556-9845
VL - 14
SP - 419
EP - 427
JO - INNOVATIONS
JF - INNOVATIONS
ER -