Salta alla navigazione principale Salta alla ricerca Salta al contenuto principale

Half-dose versus full-dose macrocyclic gadolinium at 3-T magnetic resonance imaging in paediatric bone and soft-tissue disease

  • G. S. Colafati*
  • , E. Rossi
  • , C. Carducci
  • , S. Piga
  • , I. P. Voicu
  • , Angela Mastronuzzi
  • , P. Toma
  • *Autore corrispondente per questo lavoro
  • IRCCS Ospedale pediatrico Bambino Gesù - Roma

Risultato della ricerca: Contributo in rivistaArticolo

Abstract

Background: Given the recent concerns about gadolinium-based contrast agent safety, dose reduction strategies are being investigated. Objective: To compare half-dose and standard full-dose gadoterate meglumine at 3-tesla (T) MRI in paediatric bone and soft-tissue diseases. Materials and methods: We prospectively enrolled 45 children (age range 2.7 months to 17.5 years, median age 8.7 years, 49 total anatomical segments) with bone and soft-tissue diseases (neoplastic, inflammatory/infectious, ischaemic and vascular) imaged at 3-T MRI. Two consecutive half-doses of gadoterate meglumine (0.05 mmol/kg body weight) were administered. Two sets of post-contrast T1-weighted images were obtained, one after the first half dose and the other after the second half dose. For qualitative analysis, three radiologists, masked to the gadolinium dose, compared the diagnostic quality of the images. For quantitative analysis, we compared signal-to-noise ratio and contrast-to-noise ratio at half and full doses. Results: Signal-to-noise ratio and contrast-to-noise ratio did not vary significantly between the two groups. Qualitative analysis yielded excellent image quality in both post-contrast image datasets (Cohen κ=0.8). Conclusion: In paediatric bone and soft-tissue 3-T MRI, it is feasible to halve the standard dose of gadoterate meglumine without losing image quality.
Lingua originaleInglese
pagine (da-a)1724-1735
Numero di pagine12
RivistaPediatric Radiology
Volume48
Numero di pubblicazione12
DOI
Stato di pubblicazionePubblicato - 2018

All Science Journal Classification (ASJC) codes

  • Pediatria, Perinatologia e Salute del Bambino
  • Radiologia, Medicina Nucleare e Diagnostica per Immagini

Keywords

  • 3-T
  • Children
  • Contrast agent
  • Contrast-to-noise ratio
  • Dose
  • Gadolinium
  • Gadoterate meglumine
  • Magnetic resonance imaging
  • Signal-to-noise ratio

Fingerprint

Entra nei temi di ricerca di 'Half-dose versus full-dose macrocyclic gadolinium at 3-T magnetic resonance imaging in paediatric bone and soft-tissue disease'. Insieme formano una fingerprint unica.

Cita questo