T1 - Evaluation of a nonradiometric system (BACTEC 9000 MB) for detection of mycobacteria in human clinical samples
AU - Zanetti, S
AU - Ardito, Fausta
AU - Sechi, L
AU - Sanguinetti, Maurizio
AU - Molicotti, P
AU - Delogu, Giovanni
AU - Pinna, Mp
AU - Nacci, Aldo
AU - Fadda, Giovanni
PY - 1997
Y1 - 1997
N2 - This study was carried out to evaluate the rate of recovery and time required for detection of mycobacteria from pulmonary and extrapulmonary human clinical samples, by using a fluorescence-quenching-based oxygen sensor (BACTEC 9000 MB; Becton Dickinson Microbiology Systems, Sparks, Md.). The results were compared with those obtained by microscopy, conventional culture in Lowenstein-Jensen (LJ) medium, and a BACTEC radiometric system (BACTEC 460 TB; Becton Dickinson). Of the 779 clinical samples processed, 364 from pulmonary sites and 415 from extrapulmonary sites, 62 (7.9%) were positive for mycobacterial isolates; of the positive samples, 59 (95.1%) were detected with the fluorescent BACTEC 9000 MB system, 57 (91.9%) were detected with the radiometric system (BACTEC 460 TB), and 43 (69.3%) were detected with LJ conventional culture. The mean times to detection of all mycobacteria with BACTEC 9000 MB and BACTEC 460 TB were similar (10.3 and 10.0 days, respectively). The results obtained indicate that the nonradiometric BACTEC (BACTEC 9000 MB) system is as efficient as Bactec 460 TB and significantly more efficient than LJ for the rapid recovery of mycobacteria from both pulmonary and extrapulmonary clinical specimens. Though the BACTEC 9000 MB system is recommended for respiratory specimens, we demonstrated that it can be successfully used also for recovery of mycobacteria from clinical specimens from various extrapulmonary sites.
AB - This study was carried out to evaluate the rate of recovery and time required for detection of mycobacteria from pulmonary and extrapulmonary human clinical samples, by using a fluorescence-quenching-based oxygen sensor (BACTEC 9000 MB; Becton Dickinson Microbiology Systems, Sparks, Md.). The results were compared with those obtained by microscopy, conventional culture in Lowenstein-Jensen (LJ) medium, and a BACTEC radiometric system (BACTEC 460 TB; Becton Dickinson). Of the 779 clinical samples processed, 364 from pulmonary sites and 415 from extrapulmonary sites, 62 (7.9%) were positive for mycobacterial isolates; of the positive samples, 59 (95.1%) were detected with the fluorescent BACTEC 9000 MB system, 57 (91.9%) were detected with the radiometric system (BACTEC 460 TB), and 43 (69.3%) were detected with LJ conventional culture. The mean times to detection of all mycobacteria with BACTEC 9000 MB and BACTEC 460 TB were similar (10.3 and 10.0 days, respectively). The results obtained indicate that the nonradiometric BACTEC (BACTEC 9000 MB) system is as efficient as Bactec 460 TB and significantly more efficient than LJ for the rapid recovery of mycobacteria from both pulmonary and extrapulmonary clinical specimens. Though the BACTEC 9000 MB system is recommended for respiratory specimens, we demonstrated that it can be successfully used also for recovery of mycobacteria from clinical specimens from various extrapulmonary sites.
KW - Bacteriological Techniques
KW - Cerebrospinal Fluid
KW - Evaluation Studies as Topic
KW - False Positive Reactions
KW - Feces
KW - Humans
KW - Mycobacterium
KW - Sputum
KW - Time Factors
KW - Urine
KW - Bacteriological Techniques
KW - Cerebrospinal Fluid
KW - Evaluation Studies as Topic
KW - False Positive Reactions
KW - Feces
KW - Humans
KW - Mycobacterium
KW - Sputum
KW - Time Factors
KW - Urine
UR - https://publicatt.unicatt.it/handle/10807/7199
UR - https://www.scopus.com/inward/citedby.uri?partnerID=HzOxMe3b&scp=0030811123&origin=inward
UR - https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=0030811123&origin=inward
U2 - 10.1128/JCM.35.8.2072-2075.1997
DO - 10.1128/JCM.35.8.2072-2075.1997
M3 - Article
SN - 0095-1137
VL - 35
SP - 2072
EP - 2075
JO - Journal of Clinical Microbiology
JF - Journal of Clinical Microbiology
IS - 8
ER -