T1 - Efficacy of computer-aided detection as a second reader for 6-9-mm lesions at CT colonography: multicenter prospective trial.
AU - Regge, Daniele
AU - Della Monica, Patrizia
AU - Galatola, Giovanni
AU - Laudi, Cristiana
AU - Zambon, Antonella
AU - Asnaghi, Roberto
AU - Correale, Loredana
AU - Barbaro, Brunella
AU - Borghi, Claudia
AU - Campanella, Delia
AU - Cassinis, Maria Carla
AU - Ferrari, Riccardo
AU - Ferraris, Andrea
AU - Golfieri, Rita
AU - Hassan, Cesare
AU - Iafrate, Franco
AU - Iussich, Gabriella
AU - Laghi, Andrea
AU - Massara, Roberto Maria
AU - Neri, Emanuele
AU - Sali, Lapo
AU - Venturini, Silvia
AU - Gandini, Giovanni
PY - 2013
Y1 - 2013
N2 - PURPOSE:
To assess the effect of computer-aided detection (CAD) as a second reader on the sensitivity and specificity of computed tomographic (CT) colonography in detecting 6-9-mm colorectal cancer (CRC) lesions.
MATERIALS AND METHODS:
Individuals with clinical indications for colonoscopy--either for symptoms or as part of participating in a surveillance program or CRC screening--were prospectively enrolled at one of 10 academic centers between July 2007 and May 2009. Institutional review board approval was obtained at each clinical site, and all participants provided written informed consent. All participants underwent CT colonography and colonoscopy on the same day. Experienced readers interpreted the CT colonography images unassisted and then reviewed all colorectal lesion-like structures pinpointed by the CAD algorithm. Segmental unblinding of CT colonoscopy findings at colonoscopy was utilized. The sensitivity and specificity of unassisted and CAD-assisted reading in identifying individuals with 6-9-mm lesions were calculated and compared by means of pairwise analysis.
RESULTS:
A total of 618 participants (mean age, 57.9 years; 54.5% male) were included in the final analysis. Of these participants, 464 (75.1%) had no lesions 6 mm or larger, and 52 (8.4%) had 6-9-mm lesions. The sensitivity of CT colonography with unassisted reading and that with CAD-assisted reading in identifying individuals with 6-9-mm lesions was 65.4% (95% confidence interval [CI]: 50.9%, 78.0%) and 76.9% (95% CI: 63.2%, 87.5%; P = .016), respectively. No significant change in specificity was observed: The specificity of CT colonography with unassisted and that with CAD-assisted reading was 91.8% (95% CI: 88.9%, 94.1%) and 90.9% (95% CI: 88.0%, 93.4%; P = .063), respectively. Evaluation of CAD candidates required an additional 1.6 minutes (25th-75th percentile: 1.0 minute to 3.4 minutes).
CONCLUSION:
The addition of CAD to reading performed by experienced readers resulted in a significant benefit in the detection of 6-9-mm polyps at CT colonography in this cohort.
AB - PURPOSE:
To assess the effect of computer-aided detection (CAD) as a second reader on the sensitivity and specificity of computed tomographic (CT) colonography in detecting 6-9-mm colorectal cancer (CRC) lesions.
MATERIALS AND METHODS:
Individuals with clinical indications for colonoscopy--either for symptoms or as part of participating in a surveillance program or CRC screening--were prospectively enrolled at one of 10 academic centers between July 2007 and May 2009. Institutional review board approval was obtained at each clinical site, and all participants provided written informed consent. All participants underwent CT colonography and colonoscopy on the same day. Experienced readers interpreted the CT colonography images unassisted and then reviewed all colorectal lesion-like structures pinpointed by the CAD algorithm. Segmental unblinding of CT colonoscopy findings at colonoscopy was utilized. The sensitivity and specificity of unassisted and CAD-assisted reading in identifying individuals with 6-9-mm lesions were calculated and compared by means of pairwise analysis.
RESULTS:
A total of 618 participants (mean age, 57.9 years; 54.5% male) were included in the final analysis. Of these participants, 464 (75.1%) had no lesions 6 mm or larger, and 52 (8.4%) had 6-9-mm lesions. The sensitivity of CT colonography with unassisted reading and that with CAD-assisted reading in identifying individuals with 6-9-mm lesions was 65.4% (95% confidence interval [CI]: 50.9%, 78.0%) and 76.9% (95% CI: 63.2%, 87.5%; P = .016), respectively. No significant change in specificity was observed: The specificity of CT colonography with unassisted and that with CAD-assisted reading was 91.8% (95% CI: 88.9%, 94.1%) and 90.9% (95% CI: 88.0%, 93.4%; P = .063), respectively. Evaluation of CAD candidates required an additional 1.6 minutes (25th-75th percentile: 1.0 minute to 3.4 minutes).
CONCLUSION:
The addition of CAD to reading performed by experienced readers resulted in a significant benefit in the detection of 6-9-mm polyps at CT colonography in this cohort.