TY - JOUR
T1 - Early post-operative anterior segment parameters modifications induced by PreserFlo MicroShunt in primary open-angle glaucoma
AU - Gambini, Gloria
AU - Carla', Matteo Mario
AU - Giannuzzi, Federico
AU - Boselli, Francesco
AU - Crincoli, Emanuele
AU - Caporossi, Tomaso
AU - Baldascino, Antonio
AU - De Vico, Umberto
AU - Savastano, Alfonso
AU - Rizzo, Stanislao
PY - 2023
Y1 - 2023
N2 - Purpose: The aim this study is to determine anterior chamber parameters variations induced by PreserFlo MicroShunt implantation, in the early post-operative days. Methods: This is a prospective observational study on 48 eyes undergoing PreserFlo MicroShunt implantation alone (n = 30) or combined with phacoemulsification (n = 18). Anterior chamber depth (ACD) and volume (ACV), central corneal thickness (CCT) and total corneal astigmatism (TCA) were evaluated pre-operatively, post-operatively at day-1 and at 1 week with the Pentacam tomography. Results: Intraocular pressure decreased significantly from 20.9 ± 4.0 to 8.0 ± 2.8 mmHg (p < 0.0001) and to 10.8 ± 3.7 mmHg (p = 0.0001) at day-1 and week-1, respectively. TCA varied significantly from baseline (1.5 ± 1.2 D) to both day 1 follow up (2.7 ± 1.9 D, p = 0.0003) and week 1 follow up (2.2 ± 1.6 D, p = 0.02). Nevertheless, only K1 showed a transient flattening at day 1, while K2 value didn’t show any statistical variation in the early post-operative period. CCT value rose significantly at day 1 (547 ± 49 vs. 529 ± 32 µm at baseline, p = 0.04), but then returned toward pre-operative values at week 1 (537 ± 39 µm, p = 0.57). In contrast, ACD values changed insignificantly from 3.3 ± 0.9 to 3.7 ± 1.0 mm at day 1 (p = 0.21), and then stabilized at 3.4 ± 0.9 mm (p = 0.82) at week 1 follow up. ACV changed from 150.0 ± 36.2 to 159.5 ± 42.1 mm3 at day 1 (p = 0.58), and successively to 153.9 ± 37.9 mm3 at week 1 follow up (p = 0.96). The subgroup analysis in eyes undergoing standalone PreserFlo implantation didn’t show significant changes in both ACD and ACV. Conclusion: PreserFlo implantation minimizes the anterior chamber modifications generated by traditional filtering surgery, inducing low and transient corneal and biometric changes only in the very early postoperative period and insignificant changes to ACD and ACV, label of its safety and minimal invasiveness.
AB - Purpose: The aim this study is to determine anterior chamber parameters variations induced by PreserFlo MicroShunt implantation, in the early post-operative days. Methods: This is a prospective observational study on 48 eyes undergoing PreserFlo MicroShunt implantation alone (n = 30) or combined with phacoemulsification (n = 18). Anterior chamber depth (ACD) and volume (ACV), central corneal thickness (CCT) and total corneal astigmatism (TCA) were evaluated pre-operatively, post-operatively at day-1 and at 1 week with the Pentacam tomography. Results: Intraocular pressure decreased significantly from 20.9 ± 4.0 to 8.0 ± 2.8 mmHg (p < 0.0001) and to 10.8 ± 3.7 mmHg (p = 0.0001) at day-1 and week-1, respectively. TCA varied significantly from baseline (1.5 ± 1.2 D) to both day 1 follow up (2.7 ± 1.9 D, p = 0.0003) and week 1 follow up (2.2 ± 1.6 D, p = 0.02). Nevertheless, only K1 showed a transient flattening at day 1, while K2 value didn’t show any statistical variation in the early post-operative period. CCT value rose significantly at day 1 (547 ± 49 vs. 529 ± 32 µm at baseline, p = 0.04), but then returned toward pre-operative values at week 1 (537 ± 39 µm, p = 0.57). In contrast, ACD values changed insignificantly from 3.3 ± 0.9 to 3.7 ± 1.0 mm at day 1 (p = 0.21), and then stabilized at 3.4 ± 0.9 mm (p = 0.82) at week 1 follow up. ACV changed from 150.0 ± 36.2 to 159.5 ± 42.1 mm3 at day 1 (p = 0.58), and successively to 153.9 ± 37.9 mm3 at week 1 follow up (p = 0.96). The subgroup analysis in eyes undergoing standalone PreserFlo implantation didn’t show significant changes in both ACD and ACV. Conclusion: PreserFlo implantation minimizes the anterior chamber modifications generated by traditional filtering surgery, inducing low and transient corneal and biometric changes only in the very early postoperative period and insignificant changes to ACD and ACV, label of its safety and minimal invasiveness.
KW - Anterior segment parameters
KW - Central corneal thickness
KW - PreserFlo MicroShunt
KW - Scheimpflug imaging
KW - Anterior segment parameters
KW - Central corneal thickness
KW - PreserFlo MicroShunt
KW - Scheimpflug imaging
UR - http://hdl.handle.net/10807/249845
U2 - 10.1007/s10792-023-02697-z
DO - 10.1007/s10792-023-02697-z
M3 - Article
SN - 0165-5701
VL - 43
SP - 3035
EP - 3044
JO - International Ophthalmology
JF - International Ophthalmology
ER -