T1 - Early outcomes of Jotec inner-branched endografts in complex endovascular aortic aneurysm repair
AU - Abisi, Said
AU - Zymvragoudakis, Vassilios
AU - Gkoutzios, Panos
AU - Sallam, Morad
AU - Donati, Tommaso
AU - Saha, Prakash
AU - Zayed, Hany
PY - 2021
Y1 - 2021
N2 - Objective: Complex aortic endografts have evolved to include inner branches to overcome specific challenges with existing technologies. We have reported the early outcomes of endovascular aortic aneurysm repair (EVAR) using a Jotec inner branched endograft (iBEVAR). Methods: All patients who had undergone complex EVARs using extra-design engineering iBEVAR (Jotec GmbH, Hechingen, Germany) from 2018 to 2020 at a single center were reviewed. The patient demographics, cardiovascular risk factors, anatomic features of the aneurysms, and target vessels were recorded. The reasons for using inner branches instead of fenestrated and standard branched endografts and the procedural details, outcomes, and reintervention during follow-up were examined. Results: A total of 110 patients were treated with branched and fenestrated endografts during the study period, of whom 18 patients had had a patient-specific custom-made iBEVAR endograft with downward inner branches. The technical success rate was 100%. A total of 68 target vessels were cannulated, and bridging stent-grafts were placed successfully in all. The reasons for choosing the iBEVAR design included unfavorable target vessel trajectory for fenestrated repair (n = 15), excessive infrarenal aortic angulation and/or adverse iliac access vessels for fenestrated repair (n = 11), the presence of a narrow aortic lumen (n = 14), and/or to reduce aortic coverage compared with that with standard outer branched repair (n = 14). We also used iBEVAR to treat type Ia endoleaks after failed EVAR with a short main body (n = 5). The median contrast volume used was 120 mL (range, 48-200 mL), with a median fluoroscopy screening time of 66 minutes (range, 35-136 minutes) and a median dose-area product of 17,832 dGy∙cm2 (range, 8260-55,070 dGycm2). No 30-day mortality and no major complications occurred. One early intervention was required for a suspected type Ib endoleak from an iliac limb and one late intervention for in-stent stenosis in a renal bridging stent-graft. One patient had died of non–aortic-related causes at 3 months. All other patients continued with follow-up with their aneurysms excluded, patent target vessels, and no type I or III endoleak identified at a median follow-up of 12 months (range, 1-26 months). Conclusions: The use of Jotec extra-design engineering endografts incorporating downward inner branches resulted in satisfactory early outcomes with a low reintervention rate. The technology has the potential to be a useful addition to our armamentarium for treating complex aortic endografts; however, long-term outcomes data are needed.
AB - Objective: Complex aortic endografts have evolved to include inner branches to overcome specific challenges with existing technologies. We have reported the early outcomes of endovascular aortic aneurysm repair (EVAR) using a Jotec inner branched endograft (iBEVAR). Methods: All patients who had undergone complex EVARs using extra-design engineering iBEVAR (Jotec GmbH, Hechingen, Germany) from 2018 to 2020 at a single center were reviewed. The patient demographics, cardiovascular risk factors, anatomic features of the aneurysms, and target vessels were recorded. The reasons for using inner branches instead of fenestrated and standard branched endografts and the procedural details, outcomes, and reintervention during follow-up were examined. Results: A total of 110 patients were treated with branched and fenestrated endografts during the study period, of whom 18 patients had had a patient-specific custom-made iBEVAR endograft with downward inner branches. The technical success rate was 100%. A total of 68 target vessels were cannulated, and bridging stent-grafts were placed successfully in all. The reasons for choosing the iBEVAR design included unfavorable target vessel trajectory for fenestrated repair (n = 15), excessive infrarenal aortic angulation and/or adverse iliac access vessels for fenestrated repair (n = 11), the presence of a narrow aortic lumen (n = 14), and/or to reduce aortic coverage compared with that with standard outer branched repair (n = 14). We also used iBEVAR to treat type Ia endoleaks after failed EVAR with a short main body (n = 5). The median contrast volume used was 120 mL (range, 48-200 mL), with a median fluoroscopy screening time of 66 minutes (range, 35-136 minutes) and a median dose-area product of 17,832 dGy∙cm2 (range, 8260-55,070 dGycm2). No 30-day mortality and no major complications occurred. One early intervention was required for a suspected type Ib endoleak from an iliac limb and one late intervention for in-stent stenosis in a renal bridging stent-graft. One patient had died of non–aortic-related causes at 3 months. All other patients continued with follow-up with their aneurysms excluded, patent target vessels, and no type I or III endoleak identified at a median follow-up of 12 months (range, 1-26 months). Conclusions: The use of Jotec extra-design engineering endografts incorporating downward inner branches resulted in satisfactory early outcomes with a low reintervention rate. The technology has the potential to be a useful addition to our armamentarium for treating complex aortic endografts; however, long-term outcomes data are needed.
KW - Aortic endografts
KW - Branched EVAR
KW - Fenestrated EVAR
KW - Inner branched EVAR
KW - Revision EVAR
KW - Aortic endografts
KW - Branched EVAR
KW - Fenestrated EVAR
KW - Inner branched EVAR
KW - Revision EVAR
UR - http://hdl.handle.net/10807/281417
U2 - 10.1016/j.jvs.2021.01.067
DO - 10.1016/j.jvs.2021.01.067
M3 - Article
SN - 0741-5214
VL - 74
SP - 871
EP - 879
JO - Journal of Vascular Surgery
JF - Journal of Vascular Surgery
ER -