Abstract
Purpose
To evaluate diagnostic accuracy of pattern electroretinogram (PERG) and confocal scanning laser optic disc morphometry in discriminating between early open-angle glaucoma (EOAG) and ocularhypertension (OHT).
Methods
Fifty-five randomly selected eyes of 55
patients, with a clinical diagnosis of
EOAG (26; Humphrey mean deviation
-7 dB) or OHT (29), were included in
the study. Both groups were matched
with respect to age, sex and family history.
PERGs were recorded in response
to sinusoidal gratings of optimal spatial
frequency (1.7 cycles/deg), square-wave
counterphased at 8 Hz. Response 2nd
harmonic amplitude was measured.
Confocal scanning laser morphometry
was performed by Heidelberg Retina
Tomograph (HRT; software 2.01).
Among the various HRT parameters,
disc area (DA), cuptodisc area ratio
(CDA), rim area (RA) and cup shape
measure (CSM) were selected for analysis.
Data were analyzed by Analysis of
Variance (ANOVA) and Receiver Operating
Characteristics (ROC) curves.
Correlation between functional and morphometric parameters was evaluated by multiple regression analysis. Results Mean PERG amplitude was smaller (p<O.Ol) in EOAG as compared to OHT eyes. Mean CDA and CSM were greater (p<O.Ol), and RA was smaller (p<O.Ol) in EOAG as compared to OHT eyes. The areas under the ROC curve were: PERG, 0.77; CDA, 0.69; RA, 0.71; CSM, 0.71 . Diagnostic accuracy did not differ significantly across measures. In the whole study population, PERG amplitudes were negatively correlated with CSM (r= -0.60, pCO.001). Conclusions: Functional and morphometric measures of early optic nerve damage display comparably good accuracy in discriminating between clinically defined EOAG and OHT eyes.
Lingua originale | English |
---|---|
pagine (da-a) | 40-41 |
Numero di pagine | 2 |
Rivista | ACTA OPHTHALMOLOGICA SCANDINAVICA. SUPPLEMENT |
Stato di pubblicazione | Pubblicato - 2000 |
Keywords
- Electroretinography
- Female
- Glaucoma, Open-Angle
- Humans
- Lasers
- Male
- Ocular Hypertension
- Optic Disk
- ROC Curve
- Reproducibility of Results