Cardiopulmonary Exercise Testing after Surgical Repair of Tetralogy of Fallot—Does Modality Matter?

Benedetta Leonardi, Fabrizio Sollazzo, Federica Gentili, Massimiliano Bianco, Elettra Pomiato, Stefani Silva Kikina, Rachel Maya Wald, Vincenzo Palmieri, Aurelio Secinaro, Giulio Calcagni, Gianfranco Butera, Ugo Giordano, Giulia Cafiero, Fabrizio Drago

Risultato della ricerca: Contributo in rivistaArticolo in rivista

Abstract

Background: Despite a successful repair of tetralogy of Fallot (rToF) in childhood, residual lesions are common and can contribute to impaired exercise capacity. Although both cycle ergometer and treadmill protocols are often used interchangeably these approaches have not been directly compared. In this study we examined cardiopulmonary exercise test (CPET) measurements in rToF. Methods: Inclusion criteria were clinically stable rToF patients able to perform a cardiac magnetic resonance imaging (CMR) and two CPET studies, one on the treadmill (incremental Bruce protocol) and one on the cycle ergometer (ramped protocol), within 12 months. Demographic, surgical and clinical data; functional class; QRS duration; CMR measures; CPET data and international physical activity questionnaire (IPAQ) scores of patients were collected. Results: Fifty-seven patients were enrolled (53% male, 20.5 ± 7.8 years at CPET). CMR measurements included a right ventricle (RV) end-diastolic volume index of 119 ± 22 mL/m2, a RV ejection fraction (EF) of 55 ± 6% and a left ventricular (LV) EF of 56 ± 5%. Peak oxygen consumption (VO2)/Kg (25.5 ± 5.5 vs. 31.7 ± 6.9; p < 0.0001), VO2 at anaerobic threshold (AT) (15.3 ± 3.9 vs. 22.0 ± 4.5; p < 0.0001), peak O2 pulse (10.6 ± 3.0 vs. 12.1± 3.4; p = 0.0061) and oxygen uptake efficiency slope (OUES) (1932.2 ± 623.6 vs. 2292.0 ± 639.4; p < 0.001) were significantly lower on the cycle ergometer compared with the treadmill, differently from ventilatory efficiency (VE/VCO2) max which was significantly higher on the cycle ergometer (32.2 ± 4.5 vs. 30.4 ± 5.4; p < 0.001). Only the VE/VCO2 slope at the respiratory compensation point (RCP) was similar between the two methodologies (p = 0.150). Conclusions: The majority of CPET measurements differed according to the modality of testing, with the exception being the VE/VCO2 slope at RCP. Our data suggest that CPET parameters should be interpreted according to test type; however, these findings should be validated in larger populations and in a variety of institutions.
Lingua originaleEnglish
pagine (da-a)N/A-N/A
RivistaJournal of Clinical Medicine
Volume13
DOI
Stato di pubblicazionePubblicato - 2024

Keywords

  • cardiopulmonary exercise testing
  • congenital heart disease
  • cycle ergometer
  • protocol selection
  • treadmill

Fingerprint

Entra nei temi di ricerca di 'Cardiopulmonary Exercise Testing after Surgical Repair of Tetralogy of Fallot—Does Modality Matter?'. Insieme formano una fingerprint unica.

Cita questo