Baseline C-Reactive Protein Serum Levels and In-Stent Restenosis Pattern After m-TOR Inhibitors Drug-Eluting Stent Implantation

  • Giampaolo Niccoli*
  • , Micaela Conte
  • , Nicola Cosentino
  • , Daniel Todaro
  • , Salvatore Brugaletta
  • , Rocco Antonio Montone
  • , Silvia Minelli
  • , Francesco Fracassi
  • , Vincenzo Galiffa
  • , Antonio Maria Leone
  • , Francesco Burzotta
  • , Italo Porto
  • , Carlo Trani
  • , Filippo Crea
  • *Autore corrispondente per questo lavoro

Risultato della ricerca: Contributo in rivistaArticolopeer review

Abstract

[Ita:]BACKGROUND: A diffuse pattern of in-stent restenosis (ISR) has been shown to have a worse prognosis when compared to a focal pattern. It is still unknown whether baseline C-reactive protein (CRP) levels predict ISR pattern. METHODS: Our database was searched retrospectively for patients presenting with ISR after m-TOR inhibitor drug-eluting stent (DES) implantation from January 2007 to December 2009. Angiographic restenosis patterns were evaluated according to the simplified Mehran classification and patients were allocated either to the diffuse or focal pattern group. Predictors of restenosis pattern were assessed among clinical, angiographic, procedural and laboratory data, including baseline high-sensitivity CRP, recorded at the time of the first percutaneous intervention. RESULTS: 72 patients (age, 65 ± 9 years; male sex, 64%) found to have ISR after DES implantation were enrolled. 34 patients presented with a focal pattern, whereas 38 patients presented with a diffuse pattern. At multivariate analysis, CRP levels were the only independent predictor of a diffuse ISR pattern [odds ratio, 2.5; 95% confidence interval, 1.4-4.3; p = 0.001)]. Rising CRP tertiles were associated with an increased rate of diffuse pattern (13% versus 26% versus 61%; p for trend = 0.0001). CONCLUSION: Baseline CRP serum levels are associated with a diffuse ISR pattern after m-TOR inhibitor DES implantation. These findings suggest that baseline inflammatory reactivity may contribute to aggressive restenosis occurring despite drug elution.
Lingua originaleInglese
pagine (da-a)16-20
Numero di pagine5
RivistaJournal of Invasive Cardiology
Volume23
Numero di pubblicazione1
Stato di pubblicazionePubblicato - 2011

All Science Journal Classification (ASJC) codes

  • Medicina Generale

Keywords

  • C-reactive Protein
  • drug-eluting stent

Fingerprint

Entra nei temi di ricerca di 'Baseline C-Reactive Protein Serum Levels and In-Stent Restenosis Pattern After m-TOR Inhibitors Drug-Eluting Stent Implantation'. Insieme formano una fingerprint unica.

Cita questo