T1 - Appropriate implantable cardioverter-defibrillator interventions in cardiac resynchronization therapy-defibrillator (CRT-D) patients undergoing device replacement: time to downgrade from CRT-D to CRT-pacemaker? Insights from real-world clinical practice in the DECODE CRT-D analysis
AU - ML, Narducci
AU - Biffi, M
AU - Ammendola, E
AU - Vado, A
AU - Campana, A
AU - DR, Potenza
AU - Iori, M
AU - Zanon, F
AU - Zacà, V
AU - Zoni, Berisso M
AU - Bertini, M
AU - Lissoni, F
AU - Bandini, A
AU - Malacrida, M
AU - Crea, F
PY - 2018
Y1 - 2018
N2 - AIM:\r\nVentricular tachycardia (VT)/ventricular fibrillation (VF) occurrence after cardiac resynchronization therapy-defibrillator (CRT-D) replacement is unknown; hence, there is no practical guideline to recommend either CRT-D or CRT-pacemaker at the time of device replacement. We observed the 1-year VT/VF occurrence after CRT-D replacement in a subanalysis of the Detect Long-term Complications after ICD Replacement (DECODE) registry.\r\n\r\nMETHODS AND RESULTS:\r\nA total of 332 consecutive patients who had undergone CRT-D replacement from 2013 to 2015 were enrolled in 36 Italian centres. The primary endpoint was the number of patients with any appropriate implantable cardioverter-defibrillator (ICD) interventions during 12-month follow-up. The secondary endpoint comprised death from any cause and appropriate ICD interventions. At replacement, 214 (64.5%) patients had a left ventricular ejection fraction ≤ 35% and 138 (41.6%) patients had a secondary prevention indication for ICD. Seventy (21.1%) patients had no longer indication to ICD therapy. During a median follow-up period of 406.5 (362-533) days, VT/VF requiring therapy delivery occurred in 57 (17%) patients, specifically in 7% of those who no longer had an ICD indication. On multivariate analysis, number of criteria for ICD replacement independently predicted appropriate ICD intervention during follow-up [hazard ratio (HR) = 1.62, 95% confidence interval (CI) 1.07-2.46; log-rank P = 0.02]. The combined endpoint of death from any cause or appropriate ICD therapy occurred in 76 (23%) patients. Only NYHA class remained associated with this combined endpoint (HR = 1.97, 95% CI 1.23-3.14; P = 0.005).\r\n\r\nCONCLUSIONS:\r\nThe DECODE registry showed the 'real-world' experience of CRT-D recipients approaching device replacement, in which 7% of patients who no longer had an indication for ICD therapy experienced appropriate ICD interventions.
AB - AIM:\r\nVentricular tachycardia (VT)/ventricular fibrillation (VF) occurrence after cardiac resynchronization therapy-defibrillator (CRT-D) replacement is unknown; hence, there is no practical guideline to recommend either CRT-D or CRT-pacemaker at the time of device replacement. We observed the 1-year VT/VF occurrence after CRT-D replacement in a subanalysis of the Detect Long-term Complications after ICD Replacement (DECODE) registry.\r\n\r\nMETHODS AND RESULTS:\r\nA total of 332 consecutive patients who had undergone CRT-D replacement from 2013 to 2015 were enrolled in 36 Italian centres. The primary endpoint was the number of patients with any appropriate implantable cardioverter-defibrillator (ICD) interventions during 12-month follow-up. The secondary endpoint comprised death from any cause and appropriate ICD interventions. At replacement, 214 (64.5%) patients had a left ventricular ejection fraction ≤ 35% and 138 (41.6%) patients had a secondary prevention indication for ICD. Seventy (21.1%) patients had no longer indication to ICD therapy. During a median follow-up period of 406.5 (362-533) days, VT/VF requiring therapy delivery occurred in 57 (17%) patients, specifically in 7% of those who no longer had an ICD indication. On multivariate analysis, number of criteria for ICD replacement independently predicted appropriate ICD intervention during follow-up [hazard ratio (HR) = 1.62, 95% confidence interval (CI) 1.07-2.46; log-rank P = 0.02]. The combined endpoint of death from any cause or appropriate ICD therapy occurred in 76 (23%) patients. Only NYHA class remained associated with this combined endpoint (HR = 1.97, 95% CI 1.23-3.14; P = 0.005).\r\n\r\nCONCLUSIONS:\r\nThe DECODE registry showed the 'real-world' experience of CRT-D recipients approaching device replacement, in which 7% of patients who no longer had an indication for ICD therapy experienced appropriate ICD interventions.
KW - Ventricular tachycardia
KW - ventricular fibrillation
KW - Ventricular tachycardia
KW - ventricular fibrillation
UR - https://publicatt.unicatt.it/handle/10807/126372
UR - https://www.scopus.com/inward/citedby.uri?partnerID=HzOxMe3b&scp=85055065641&origin=inward
UR - https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85055065641&origin=inward
U2 - 10.1093/europace/eux323
DO - 10.1093/europace/eux323
M3 - Article
SN - 1099-5129
VL - 20
SP - 1475
EP - 1483
JO - Europace
JF - Europace
IS - 9
ER -