Background: The aim of the study was to evaluate the safety and functional outcome of a small incision, sutureless vitrectomy in the treatment of idiopathic epiretinal membranes (ERM) compared with a standard 20-gauge vitrectomy system. Methods: Forty-six consecutive patients with idiopathic ERM were recruited for this study and prospectively evaluated. In group 1 (n=26) we used a transconjunctival sutureless 25-gauge vitrectomy system (TSV), patients in group 2 (n=20) were operated on using a standard 20-gauge vitrectomy system. The ERM was removed and the internal limiting membrane (ILM) was peeled in all eyes. Surgery-related complications, operating time, intraoperative balanced salt solution (BSS) consumption, postoperative discomfort, postoperative intraocular inflammation, lens opacification, and long-term visual outcome are reported and compared. Results: No surgery-related complications were observed in either group. Operating time was shorter in group 1 compared with group 2 (mean 15.6 and 29.6 min respectively). Intraoperative amount of BSS consumption was less in group 1 (mean 28 ml in group 1 and 42 ml in group 2). Postoperative discomfort and intraocular inflammation were significantly reduced in the 25-gauge group. In the 20-gauge group cataract formation requiring surgery was observed in two eyes. Visual acuity improved significantly in both groups. The 25-gauge group improved on average by more lines of vision and the improvement in vision was more rapid. Conclusions: The TSV system is a safe and efficient surgical technique for ERM surgery. Operating time is significantly reduced, minimizing surgery-induced trauma, and reducing postoperative intraocular inflammation and the patients' discomfort. The incidence of cataract formation may be less using TSV. Postoperative recovery is accelerated.
Lingua originaleEnglish
pagine (da-a)472-479
Numero di pagine8
RivistaGraefe's Archive for Clinical and Experimental Ophthalmology
Volume244
DOI
Stato di pubblicazionePubblicato - 2006

Keywords

  • 25-gauge
  • idiopathic epiretinal membrane
  • sutureless pars plana vitrectomy

Fingerprint

Entra nei temi di ricerca di '25-gauge, sutureless vitrectomy and standard 20-gauge pars plana vitrectomy in idiopathic epiretinal membrane surgery: A comparative pilot study'. Insieme formano una fingerprint unica.

Cita questo