Skip to main navigation Skip to search Skip to main content

Usability, performance and safety of a new device for degenerative mitral regurgitation: in vivo chronic evaluation

  • University of Ferrara
  • Technion-Israel Institute of Technology
  • San Raffaele Scientific Institute

Research output: Contribution to journal › Article

Abstract

OBJECTIVES: This study aimed to evaluate the usability, performance and safety of an innovative mitral valve device in the chronic setting characterized by an intraventricular bridge, which enables artificial chordae anchoring and/or direct posterior leaflet fixation.METHODS: Ten female sheep were employed and underwent device implantation. Any interference of the device with leaflet motion, ease of device use, correct chordae length estimation and implantation were evaluated. Post-procedural valve competence and device performance were verified by periodic postoperative echocardiograms and laboratory examinations. Following euthanasia, gross anatomy and histology evaluation of the hearts and valves were performed to detect tissue abnormalities and inflammation reaction related to the device.RESULTS: The procedure was successfully completed in all 10 sheep. Lengths of the 2 chordae implanted were 23 (21.5-24) mm and 23 (22.5-24) mm. The time required to suture both pairs of the artificial chordae was 2.7 +/- 0.7 min. At the 3-month follow-up, left ventricular function was normal. The transvalvular peak pressure gradient was 9 (7.5-10) and the mean gradient was 4 (3.5-4) mmHg. Upon necropsy and histological evaluation, no damage to left ventricle wall, valve leaflets, chordae and papillary muscles and absence of thrombus formation and inflammatory reaction were observed. Radiological images showed neither fracture of the device nor calcifications. Laboratory tests showed no signs of haemolysis.CONCLUSIONS: In vivo late tests confirmed the ease of correct chordal length estimation prior to implantation, short operative time and usability in flailed anterior leaflet repair. The absence of negative impact of the device on mitral leaflets motion, function and structure and successful repair might suggest that the device would be useful in complex degenerative mitral disease.
Original languageEnglish
Pages (from-to)1-10
Number of pages10
JournalInteractive Cardiovascular and Thoracic Surgery
Volume35
DOIs
Publication statusPublished - 2022

Keywords

  • Chordae implantation
  • Mitral valve repair
  • Mitral ring
  • Mitral regurgitation

Fingerprint

Dive into the research topics of 'Usability, performance and safety of a new device for degenerative mitral regurgitation: in vivo chronic evaluation'. Together they form a unique fingerprint.

Cite this