Skip to main navigation Skip to search Skip to main content

The role of ultrasound-guided tru-cut biopsy in ovarian cancer: a systematic review of its safety, adequacy, and accuracy with meta-analysis of diagnostic performance

  • Munachiso Iheme Ndukwe
  • , Matteo Pavone
  • , Dominik Habes*
  • , Nicolo' Bizzarri
  • , Martin Stepan
  • , Petra Bretová
  • , Floriana Mascilini
  • , Dominik Karasek
  • , Denisa Pohankova
  • , Akaninyene Ubom
  • , Jana Marie Havigerova
  • , Jiri Haviger
  • , Igor Sirak
  • *Corresponding author
  • Charles University
  • Institute of Image-Guided Surgery
  • University of Hradec Kralove

Research output: Contribution to journalArticle

Abstract

Objectives: To analyze the safety, adequacy and accuracy of ultrasound-guided tru-cut biopsy in the diagnosis of ovarian cancer. Methods: A systematic search of PubMed, Web of Science, and Scopus was conducted through June 2024. Studies meeting predefined criteria were included in the review. The quality of diagnostic accuracy studies was assessed using QUADAS-2. A meta-analysis was performed on studies reporting complete 2 × 2 diagnostic data. Results: A total of 2,250 articles were initially screened, and after the removal of duplicates, 54 articles were deemed eligible for full-text assessment. Ultimately, 18 studies, comprising 1,867 patients who underwent ultrasound-guided tru-cut biopsy, were included in the systematic review. A total of 16 complications were reported across 1,898 biopsies performed in the included studies, resulting in a mean complication rate of 0.58% (95% CI: 0.187– 0.964%). Adequacy for histological and immunohistochemical examination after one attempt was reported in 16 studies, with a mean adequacy rate of 95.1% (95% CI: 92.69– 97.50%) and a median rate of 95.97%. Diagnostic accuracy was assessed in 13 studies, revealing a mean diagnostic accuracy of 95.54% (95% CI: 93.19– 97.89%) and a median of 97.48%.In the meta-analysis of 10 studies, pooled sensitivity was 98.6%, specificity 41.9%, positive predictive value (PPV) 99.0%, and negative predictive value (NPV) 47.2%, with high heterogeneity observed in specificity and NPV estimates. Conclusions: Ultrasound guided tru-cut biopsy is a safe and effective diagnostic method, demonstrating a high adequacy rate for histological and immunohistochemical analysis. It shows excellent performance in confirming malignancy and supports preoperative decision making. To further define its role in the diagnostic pathway for ovarian cancer, additional prospective multicenter studies are needed—both to validate its reliability in negative cases and to ensure tissue adequacy for advanced molecular testing in the context of personalized medicine.
Original languageEnglish
Pages (from-to)N/A-N/A
JournalJournal of Ovarian Research
Volume18
Issue number1
DOIs
Publication statusPublished - 2025

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 3 - Good Health and Well-being
    SDG 3 Good Health and Well-being

All Science Journal Classification (ASJC) codes

  • Oncology
  • Obstetrics and Gynaecology

Keywords

  • Core needle biopsy
  • Ovarian cancer
  • Systematic review
  • Tru-cut biopsy
  • Ultrasound

Fingerprint

Dive into the research topics of 'The role of ultrasound-guided tru-cut biopsy in ovarian cancer: a systematic review of its safety, adequacy, and accuracy with meta-analysis of diagnostic performance'. Together they form a unique fingerprint.

Cite this