Impianto di ventilazione e condizionamento a contaminazione controllata (VCCC), contaminazione microbica dell’aria e infezione del sito chirurgico in interventi di artroprotesi: il Progetto Ischia del GISIO-SItI

Translated title of the contribution: [Autom. eng. transl.] Ventilation and conditioning system with controlled contamination (VCCC), microbial contamination of the air and infection of the surgical site in arthroplasty operations: the Ischia Project by GISIO-SItI

C Pasquarella, A Agodi, F Auxilia, M Barchitta, Ml Cristina, D D'Alessandro, Umberto Moscato, I Mura, M Nobile, F Rossi, S Tardivo, Mv Torregrossa

Research output: Contribution to journalArticlepeer-review

Abstract

Heating, ventilation air conditoning (HVAC) systems, microbial air contamination and surgical site infections in hip and knee arthroplasties: The ISChIA project by GISIO-SItI Aim of the ISChIA Project was to evaluate the association between heating, ventilation and air conditioning (HVAC) systems, microbial air contamination, and surgical site infections in hip and knee arthroplasty as a contribution to the debate on the protective role of unidirectional airflow in surgical site infections. A total of 14 hospitals and 28 operating theatres were included in the study. During each operation, microbial air contamination was evaluated by means of passive and active samplings. The number of people and the number of door openings were also recorded. Surgical site infection surveillance was conducted according to the HELICS protocol. The preliminary results show that low microbial contamination is associated with a lower risk of surgical site infection, although no significant protective effect is evident. Despite the economic cost of equipping an operating theatre with a unidirectional air flow system, air microbial values in such theatres were often higher than expected, suggesting that such theatres were badly managed. Further studies on this controversial subject are thus needed as well as training interventions aimed at improving the behaviour of operators.
Translated title of the contribution[Autom. eng. transl.] Ventilation and conditioning system with controlled contamination (VCCC), microbial contamination of the air and infection of the surgical site in arthroplasty operations: the Ischia Project by GISIO-SItI
Original languageItalian
Pages (from-to)377-381
Number of pages5
JournalANNALI DI IGIENE MEDICINA PREVENTIVA E DI COMUNITÀ
Volume25 Supplemento 1
Publication statusPublished - 2013

Keywords

  • HVAC SYSTEM
  • IMPIANTO VCCC
  • OPERATING THEATRE
  • SALA OPERATORIA

Fingerprint

Dive into the research topics of '[Autom. eng. transl.] Ventilation and conditioning system with controlled contamination (VCCC), microbial contamination of the air and infection of the surgical site in arthroplasty operations: the Ischia Project by GISIO-SItI'. Together they form a unique fingerprint.

Cite this