Skip to main navigation Skip to search Skip to main content

Feasibility and diagnostic yield of small-bowel capsule endoscopy in patients with surgically altered gastric anatomy: the SAGA study

  • Xavier Dray*
  • , Maria Elena Riccioni
  • , Gabriele Wurm Johansson
  • , Martin Keuchel
  • , Guillaume Perrod
  • , Antoine Martin
  • , Annalisa Tortora
  • , Artur Nemeth
  • , Peter Baltes
  • , Enrique Pérez-Cuadrado-Robles
  • , Stefania Chetcuti Zammit
  • , Phey Shen Lee
  • , Romain Leenhardt
  • , Anastasios Koulaouzidis
  • , I CARE Group
  • *Corresponding author
  • Sorbonne Université
  • Lund University
  • Asklepios Klinik St. Georg
  • Université de Paris
  • Hôpital Henri Mondor
  • Agaplesion Bethesda Krankenhaus Bergedorf
  • Hospital Morales Meseguer
  • Royal Hallamshire Hospital
  • South Tyneside and Sunderland NHS Foundation Trust
  • New Royal Infirmary of Edinburgh
  • Pomeranian Medical University in Szczecin

Research output: Contribution to journalArticle

Abstract

Background and aims: Little is known about small-bowel (SB) capsule endoscopy (CE) in patients with a history of gastric surgery. This study aims to evaluate the feasibility and diagnostic yield (DY) of orally ingested SB-CE in patients with surgically altered gastric anatomy.\r\n\r\nMethods: Twenty-four European centers retrospectively identified patients who had SB-CE after total or subtotal gastrectomy. The primary outcome was the DY of SB-CE (intermediate P1 to highly P2 relevant findings). Secondary outcomes were gastric and SB transit times, completion, cleanliness, and adverse event rates.\r\n\r\nResults: Studied were 248 procedures from 243 patients (mean age, 62 years) with a history of partial gastrectomy (Billroth I, 13.1%; Billroth II, 34.6%), total gastrectomy (7.4%), Whipple procedure (12.8%), sleeve gastrectomy (7.2%), or gastric bypass surgery (24.7%). Obscure GI bleeding was the most frequent indication (85.1%). SB completion rate was 84.3%. One capsule retention in the SB was noted (adverse event rate, .4%). Median SB transit time was 286 minutes (interquartile range [235; 387]). Cleanliness was rated as adequate in 92.1% of procedures. After exclusion of abnormalities found at the upper anastomotic site, the DY was 43.6%, with inflammatory/ulcerated lesions observed more frequently (23.4%) than vascular lesions (21.0%).\r\n\r\nConclusions: SB-CE seems to be feasible and safe in selected patients with a history of major gastric surgery and comes with a high DY. The spectrum of abnormal SB findings in these patients may be different from what is known from the literature in nonoperated patients.
Original languageEnglish
Pages (from-to)589-597.e1
Number of pages9
JournalGastrointestinal Endoscopy
Volume94
Issue number3
DOIs
Publication statusPublished - 2021

All Science Journal Classification (ASJC) codes

  • Radiology Nuclear Medicine and imaging
  • Gastroenterology

Keywords

  • small-bowel capsule endoscopy

Fingerprint

Dive into the research topics of 'Feasibility and diagnostic yield of small-bowel capsule endoscopy in patients with surgically altered gastric anatomy: the SAGA study'. Together they form a unique fingerprint.

Cite this