Skip to main navigation Skip to search Skip to main content

Cross-modality Accuracy of Dual-step, Prospectively Electrocardiography-triggered Dual-source Computed Tomography Compared With Same-day Echocardiography and Cardiac Magnetic Resonance Imaging in the Follow-up of Heart-transplant Patients

Research output: Contribution to journalArticlepeer-review

Abstract

Purpose: An accurate evaluation of left ventricular volumes, mass, and ejection fraction (EF) and an early exclusion or detection of significant coronary artery disease or cardiac allograft vasculopathy are mandatory for clinical management and prognosis assessment of heart-transplanted patients (HTP). The purpose of this article was to evaluate the role of dual-step prospective electrocardiographytriggered Dual-Source CT (pECGdual-step-DSCT) in HTP for the assessment of left-ventricular function, in comparison with echocardiography (echo) and cardiac magnetic resonance (CMR) performed on the same day, and of the coronary arteries as well.\r\nMaterials and Methods: Left-ventricular EF, end-diastolic volume, end-systolic volume, stroke volume, cardiac output (CO), and mass\r\nwere assessed in 11 HTP by pECGdual-step-DSCT in comparison with CMR and echo performed on the same day. During all the\r\nexaminations, the heart rate was recorded. CT coronary artery assessment was also performed.\r\nResults: Heart rate was lower during DSCT (75.6±7.8 bpm; P<0.001). EF resulted slightly lower for DSCT (55.7%±5.0%;\r\nP≥0.05) in comparison with CMR (57.8%±5.3%; P≥ 0.05) and echo (59.2%±5.6%; P≥0.05). DSCT showed statistically significant\r\nhigher end-diastolic volume (153.7±24.2 mL), end-systolic volume (67.8±11.5 mL), and stroke volume (85.9±17.6 mL)\r\n(P< 0.01 up to 0.001) than CMR, but with a high correlation (P< 0.001). Cardiac output was almost similar for DSCT versus\r\nCMR, with a very high correlation coefficient (r=0.914; P<0.001). DSCT showed higher mass values than CMR (P<0.001), but with\r\na high correlation (r=0.866; P<0.001). DSCT versus echo results were less correlated. No significant coronary artery disease was\r\ndetected.\r\nConclusion: pECGdual-step-DSCT allows reliable assessment of leftventricular function in HTP, with good agreement and correlation\r\nwith CMR, within a global diagnostic approach including coronary artery evaluation in one single-volume acquisition.
Original languageEnglish
Pages (from-to)217-224
Number of pages8
JournalJournal of Thoracic Imaging
Volume2018
Issue number33
DOIs
Publication statusPublished - 2018

All Science Journal Classification (ASJC) codes

  • Radiology Nuclear Medicine and imaging
  • Pulmonary and Respiratory Medicine

Keywords

  • cardiac imaging
  • cardiac magnetic resonance
  • cardiac transplantation
  • dual-source computed tomography
  • left-ventricular function

Fingerprint

Dive into the research topics of 'Cross-modality Accuracy of Dual-step, Prospectively Electrocardiography-triggered Dual-source Computed Tomography Compared With Same-day Echocardiography and Cardiac Magnetic Resonance Imaging in the Follow-up of Heart-transplant Patients'. Together they form a unique fingerprint.

Cite this